INSTALLATION Flexible Pipe Installation.
1.FITTING THE APPLIANCE AND CABINET
It is recommended that a 3/8, 1100mm long angled bayonet flexible hose (BFS) and a ½" straight socket (BFS) be used for the installation. However any approved hose of the right length can be used.
IMPORTANT: Flexible tubing used must comply with B.S. 669 current editions L.P.G. flexible connections must be of a type suitable for L.P.G. and capable of operation up to 50mbar and carry a red stripe, band or lable.
NOTE:Only liquid sealants can be used in threaded gas connections. Do not use P.T.F.E. tape.
1Make suitable arrangements for gas and electric supplies into the installation site. Preferably a junction box or 3 pin earth socket should be situated at the back of the cabinet below the oven.
2The electrical connection to the appliance is at the rear bottom right hand side, the junction box or socket should be positioned accordingly.
3Fit the cabinet as Fig.1, making sure that it is level.
4When unpacking the appliance keep it on its polystyrene base until it is put into the cabinet to avoid damage. Do not allow young children to play with any part of the packaging. After installation, please dispose of the packaging with due regard to the environment, your local authority can arrange this.
NOTE: It is imperative that the appliance is left in the base to protect both the appliance and the floor.
5Remove the oven and grill doors
i)Open door fully.
ii)Rotate the hinge stirrups to there forward position. (See Fig. 2).
iii)To remove the door, clear the hinges by raising the door slightly whilst pulling towards you.
Fig.2
HINGE
STIRRUP
6Remove the fascia panel .
i)Remove the gas control knobs, springs, bezels and timer control knobs.
ii)Remove the four screw (two each side) which are visible on the underside of the fascia. Fig.3.
iii)Tilt the bottom of the fascia panel out over. Withdraw the fascia panel by moving it down over to disengage it from the top fixing lugs. Take care not to lose the two
rubber grommets from the timer.
NOTE: The thermostat and grill discs will remain attached to the |
| |||
fascia panel. When refitting the control knobs and bezels, the |
| |||
drive pins on the rear of the bezel must first be located in the disc | Fig.3 | |||
carrier. The knob and spring can now be fitted onto the control | ||||
| ||||
spindle. To prevent the top fascia panel mounts becoming slack, it |
| |||
may be necessary to adjust the top fixing lugs. |
| |||
|
|
|
|
39