similar characteristics: H05
To connect directly to the mains, a suitable omnipolar switch complying with current standards and with a contact gap of at least 3 mm must be installed between the appliance and the electrical system.
The yellow/green earth wire must not be interrupted by the switch. The brown phase wire (coming from terminal "L" on the terminal block) must always be connected to the power supply phase.
In any case the power cable must be positioned in such a way that no part of it reaches a temperature of 50°C higher than the ambient temperature.
The cable is guided by means of clamps fixed to the side of the cabinet, in order to avoid any contact with the equipment beneath the cooktop.
The Manufacturer declines any liability if the
Ensure that the hob supply cord does not come into contact with surfaces with temperatures higher than 50 deg. C.
The replacement of electric cable must be carried out exclusively by the service for- ce centre or by personnel with similar competencies, in accordance with the current regulations.
Neutral
Earth (yellow/green)
15