Ducting Connection

INSTALLING THE COOKER HOOD

Ducting Connection

Connect the ducting chosen to:

the Ø150mm ducting spigot on top of the motor housing, or the Ø150-120mm ducting spigot item 9 and secure using the jubilee clips item 25.

A Ø120-125mm collar item 9a is provided to fit over the Ø120mm ducting spigot when 125mm ducting is fitted.

If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating boiler, then its flue must be of the room sealed or balanced flue type.

If other types of flue or appliances are fitted sure that there is an adequate supply of air to the room.

The cooker ducting (extraction mode) must never be connected to central heating flues, radiators or water heaters etc.

Recirculation

The cooker hood is supplied specified for use in the recirculation mode, with the charcoal filter fitted.

In the recirculation mode contaminated air is passed through the charcoal filter to be purified and recirculated into the kitchen through the grille outlets on either side of the chimney.

Recirculation Connection

Insert reducer flange 9 on the extractor outlet.

Push fit connector 15 onto the reducer flange.

Insert extension piece 14.2 sideways into connector 15 making sure that the outlet corresponds with the mouth of the chimney

 

9 + 9a

ø 150

ø 125

15

14.2

9

16