Fitting the Canopy Hood

INSTALLING THE COOKER HOOD

Fitting the Canopy Hood

Before starting to fix the canopy, tighten the two screws Vr located on the canopy mouiunting brackets.

-Hook the canopy onto the screws (not supplied).

-Tighten up the screws.

-Adjust the screws item Vr to level the canopy.

The fixings come together with the splashback.

Ducting the Cooker Hood

When installing the cooker hood in the ducting mode, connect the hood using either Ø150 or 120mm flexible or rigid pipe.

The choice of ducting should be specified by the installer but Ø150mm rigid ducting will ensure the best performance possible.

The ducting used must be manufactured from fire retardent material conforming to the relevant British Standard or DIN 4102-B1.

Ducting the Cooker Hood Fitting the Ducting

-To install Ø120mm ducting, fit the ducting spigot Ø150-120mm item 9 on to the spigot on top of the canopy.

-To install Ø150mm ducting, fit the ducting on the spigot on top of the canopy.

-Remove the activated charcoal filter.

Recirculating the Cooker Hood

The cooker hood is supplied specified for use in the recirculation mode, with the charcoal filter already fitted.

Vr

ø 150

ø 120

9

Fitting the Recirculation Duct

-

Assemble the two halves of the ducting

15

14.1

 

 

 

extension pipe item 14.

8b

 

-

Push-fit the extension pipe on to the

 

8a

 

ducting spigot on top of the canopy.

 

 

 

 

-

Push-fit the recirculation adapter item 15

14

 

 

on to extension pipe item 14.

 

 

-

Insert the recirculation outlet extensions

 

 

 

item 14.4 into the recirculation adapter

 

 

 

item 15.

 

 

-

The recircualtion grilles item 8a and 8b

 

 

 

must be fitted after the lower chimney

 

 

 

item 2.2 has been fitted.

 

 

Electrical Connection

Connect the hood to the mains supply via a double-pole switch having a contact gap of at least 3mm.