INSTALLATION

INSTALLING THE APPLIANCE

1.Remove all packaging and check carefully for any signs of damage.

2.This oven is designed to fit into a 360mm high cupboard as standard.

When fitting into a 350mm high cupboard:- Unscrew and remove the 4 feet from the bottom of the oven. There are 3 tall feet and 1 short foot. Replace the 3 tall feet with those provided in the accessory pack. Do not replace the short foot.

3.If fitting the microwave oven above a conventional oven (position A) then use the mylar sheet provided.

a.Cut the Mylar sheet to fit the internal width of the unit.

b.Peel back the protective cover on the tape and fix

to the rear of

Mylar sheet

 

the shelf so

 

 

 

that it covers

Internal

 

the service

width

gap. (See

 

 

 

diagram).

Conventional

gap

Service

 

oven

 

 

4.Fit the appliance into the kitchen cupboard slowly, and without force, until the front frame of the oven seals against the front opening of the cupboard.

5.Ensure the appliance is

stable and not leaning.

 

Ensure that a 5mm gap is

5 mm

kept between the cupboard

 

door above and the top of

 

the frame (see diagram).

 

6.Fix the oven in position with the screws provided.

The fixing points are located on the top and bottom corners of the oven (see diagram, item 9, on page 4).

7.It is important to ensure that the installation of this product conforms to the instructions in this operation manual and the hob or conventional oven manufacturer’s installation instructions.

Chimney

Chimney

SAFE USE OF THE APPLIANCE

If fitting the microwave in position B or C:

The cupboard must be a minimum of 500 mm (E) above the worktop and must not be installed directly above a hob.

This appliance has been tested and approved for use near domestic gas, electric and induction hobs only.

Sufficient space between hob and microwave should be allowed to prevent overheating of microwave oven, surrounding cupboard and accessories.

Do not operate the hob without pans when the microwave oven is operating.

Care should be taken when attending to the microwave oven while the hob is on.

Position A

Position B

Position C

Position D

E

Conventional

oven

POSITION

NICHE SIZE

CHIMNEY

Gap Between

 

W

D

H

(min)

Cupboard & Ceiling

A

560 x 550 x 360

50

50

B + C

460 x 300 x 350

18

50

 

460 x 300 x 360

18

50

 

560 x 300 x 350

18

50

 

560 x 300 x 360

18

50

D

460 x 500 x 350

18

50

 

460 x 500 x 360

18

50

 

560 x 500 x 350

18

50

 

560 x 500 x 360

18

50

 

 

 

 

 

 

Measurements in (mm)

30

Page 32
Image 32
Zanussi ZM175ST, ZM176ST manual Installation, Installing the Appliance