Serial Interface The printer’s serial port is configured with the Communication Y command for the printer. The printer supports Configuration interface data rates from 1200 to 38,400 baud.
See the programmer's manual for details.
The printer’s serial port default configuration is: 9600 baud
8 bit data
1 stop bit No parity
Wiring
Host  | 
  | Printer  | ||
  | Pin #  | Pin #  | 
  | 
  | 
N/C  | 1  | 1  | 
  | +5 Volts*  | 
RxD  | 2  | 2  | 
  | TxD  | 
TxD  | 3  | 3  | 
  | RxD  | 
DTR  | 4  | 4  | 
  | N/C  | 
GND  | 5  | 5  | 
  | GND  | 
DSR  | 6  | 6  | 
  | RDY  | 
  | ||||
RTS  | 7  | 7  | 
  | N/C  | 
CTS  | 8  | 8  | 
  | RDY  | 
  | ||||
RI  | 9  | 9  | 
  | N/C  | 
  | Female   | 
  | 
  | |
  | 
  | 
  | ||
Host  | 
  | Printer  | ||
  | Pin #  | Pin #  | 
  | 
  | 
N/C  | 8  | 1  | 
  | +5 Volts*  | 
RxD  | 3  | 2  | 
  | TxD  | 
TxD  | 2  | 3  | 
  | RxD  | 
DTR  | 20  | 4  | 
  | N/C  | 
GND  | 7  | 5  | 
  | GND  | 
DSR  | 6  | 6  | 
  | RDY  | 
  | ||||
RTS  | 4  | 7  | 
  | N/C  | 
CTS  | 5  | 8  | 
  | RDY  | 
  | ||||
RI  | 22  | 9  | 
  | N/C  | 
  | 
  | 
  | 
  | 
  | 
Female 
*+5 volts at 150 mA for external device (e.g. KDU or scanner)
24  |