Zebra )300 User’s Guide

Here is the command description for the Set Communications command (refer to your ZPL II Programming Guide for additional programming information):

^SCa,b,c,d,e,f

where

a = baud rate (110 - 19200 baud)

b = word length (7 or 8 data bits)

c = parity (N = none, E = even, O = odd)

d = stop bits (1 or 2 )

e = handshake (X = XON/XOFF, D = DTR/DSR)

f = Zebra protocol (Y = yes, N = no)

If you do not specify a new setting for a parameter, it remains unchanged (it does not change to the default value).

Adjusting the Darkness of the Printing

If you are using BAR-ONE or other software, adjust the relative darkness setting as indicated in that software. Or, if you are using ZPL II, send the ^MD (Media Darkness) ZPL II command.

ZebraNet Option

You may choose to network your Zebra A300 printer. Contact your distributor for information about ZebraNet™ micro print server—ethernet connectivity for your Zebra A300 printer.

￿%