Zebra )300 User’s Guide

 

 

 

 

 

 

 

 

Table 5: Specifications (Continued)

 

 

 

 

 

Media requirements

Zebra recommends use of Zebra brand media. All media

 

 

must be direct thermal media. Media may be continuous,

 

 

die-cut, or notched. Notched media must have a notch

 

 

which is 1/4² wide ´ 3/32² long located on the left side

 

 

of the label as it feeds through the printer.

 

Physical size (L ´ W ´ H)

9.7² ´ 7.0² ´ 6.0²

249 mm ´ 179 mm ´

 

 

 

154 mm

 

Weight (without media)

3.35 lb

1.52 kg

 

Temperature

Operating

50° to 104° F

10° to 40° C

 

range

Storage

-4° to 140° F

-20° to 60° C

 

Relative humidity,

operation and

10 to 90% R.H.

 

 

storage

 

 

 

 

Electrical

 

External 120 or 230 VAC power supply, depending on

 

 

which model you ordered. Additional custom line cords

 

 

may also be available.

 

 

Communications

 

36-pin Centronics® -compatible parallel port and RS-232

 

 

serial port; contact your distributor for information about

 

 

ZebraNet™—ethernet connectivity for the

A300.

Agency approvals

 

• UL 544 Medical Equipment Standard Part 42.5

 

 

• CSA 22.2 No. 950 Canadian Safety Standard

 

 

• Carries the CE mark of compliance.

 

 

 

• IEC 950/EN 60950 International Safety S tandard

 

 

• FCC Part 15 Subpart B level A Electromagnetic Radia-

 

 

tion Standard

 

 

 

 

• AAME 4.3.2 Medical Standard

 

 

 

• UL 1950 Domestic Safety Standard

 

 

 

SOR/88-475 Canadian Electromagnetic Radiation

 

 

Standard

 

 

 

 

EN50082-1 International Immunity Standard

 

 

C.I.S.P.R.-22 Class B European Electromagnetic Radia-

 

 

tion Standard

 

 

Processor/memory

 

32-bit microcontroller, 512 kB DRAM

 

Power line cord

 

• The overall length must be less than 12.5 ft (3.8 meters)

 

 

• It must be rated for at least 3 A, 250 V.

 

 

 

• The chassis ground (earth) MUST be connected to

 

 

assure safety and reduce electromagnetic interference.

 

 

The ground connection is handled by the third wire

 

 

(earth) in the power line cord. See Figure 7.

 

 

The AC power plug and IEC 320 connector must bear

 

 

the certification mark of at least one international safety

 

 

organization (some examples are shown in Figure 2.)

Parallel data cable

 

For maximum reliability, use a parallel data cable no

 

 

longer than 6 ft (1.8 m).

 

 

!