9. Maintenance

MA8

MA9

MA10

MA11

WARNING

When returning the filter, use a pinch not to be folded the suction pipe.

4. Spark plug

Clean the electrodes with a wire brush and adjust the gap to 0.6mm. (MA8)

Replacement plug:

Champion RCJ-7Y

WARNING

After spark plug maintenance, reinstall the plug and plug cap firmly. (TORQUE: 14.7~17.6 N.m./150~180 kg-cm) Or it may cause the fire accident. (MA9)

(1)Plug

(2)Plug cap

5. Sprocket

Check for extensive wear, and replace it when the teeth are worn over 1.0mm. (MA10)

6. Guide bar

The bar rail should always be a square. Check for wear of the bar rail. Apply a ruler to the bar and the outside of a cutter. If a gap is observed between them, the rail is normal. Otherwise, the bar rail is worn. Such a bar needs to be corrected or replaced.(MA11)

(1)Ruler

(2)Gap

(3)No gap

(4)Chain tilts

21

Page 21
Image 21
Zenoah G2500TS manual MA8 MA9, Ruler Gap No gap Chain tilts