13. Troubleshooting guide

English

Case 1. Starting failure

CHECK

PROBABLE CAUSES

ACTION

fuel tank

incorrect fuel

fuel filter

fuel filter is clogged

carburetor adjustment screw

out of normal range

sparking (no spark)

spark plug is fouled/wet

 

plug gap is incorrect

spark plug

disconnected

drain it and with correct fuel

clean

adjust to normal range

clean/dry

correct (GAP: 0.6 – 0.7 mm)

retighten

Case 2. Engine starts but does not keep running/Hard re-starting.

CHECK

PROBABLE CAUSES

ACTION

fuel tank

incorrect fuel or staled fuel

carburetor adjustment screw

out of normal range

muffler,cylinder (exhaust port)

carbon is built-up

air cleaner

clogged with dust

cylinder fin, fan cover

clogged with dust

drain it and with correct fuel

adjust to normal range

wipe away

wash

clean

When your unit seems to need further service, please consult with our service shop in your area.

13. Guide de localisation des pannes

 

 

Français

 

 

 

 

 

 

1er cas : Défaut de démarrage

 

 

 

 

 

 

 

 

VERIFICATION

CAUSES PROBABLES

ACTION

réservoir de carburant

carburant incorrect

vidanger et remplacer le carburant

filtre à carburant

filtre à carburant colmaté

nettoyer

vis de réglage de carburateur

déréglé

refaire le réglage

allumage

bougie sale ou noyée

nettoyer ou sécher

 

Jeu d’électrodes incorrect

régler le jeu (de 0,6 à 0,7 mm)

Bougie d’allumage

débrancher

resserrer

 

2ème cas : Le moteur démarre mais ne reste pas en marche ou est difficile à redémarrer

 

 

 

 

 

VERIFICATION

 

CAUSES PROBABLES

 

ACTION

réservoir de carburant

carburant incorrect

vidanger et remplacer le carburant

vis de réglage de carburateur

déréglé

refaire le réglage

silencieux, cylindre

dépôt de calamine

retirer

filtre à air

colmaté de poussière

nettoyer

ailette de cylindre/flasque de ventilateur

colmaté de poussière

nettoyer

Si la machine nécessite des opérations d’entretien plus élaborées, contacter le centre de service après-vente le plus proche.

13. Guía de localización y solución de problemas

 

Español

 

 

 

 

Caso 1. El motor no arranca

 

 

 

 

 

 

COMPROBAR

POSIBLES CAUSAS

ACCIÓN

Tanque de combustible Filtro de combustible Tornillo de ajuste del carburador Explosión (no hay chispa)

Bujía

Combustible incorrecto

El filtro de combustible está obstruido.

Fuera del margen normal

La bujía está sucia/mojada.

La distancia interelectródica es incorrecta

Desconectada

Vaciar y llenar con el combustible correcto

Limpiar

Ajustar al margen normal

Limpiar/secar

Corregir (DISTANCIA INTERELECTRÓDICA: 0,6 – 0,7 mm)

Reajustarlo

Caso 2. El motor arranca pero no se mantiene en marcha./Dificultad para volver a arrancar el motor.

COMPROBAR

POSIBLES CAUSAS

ACCIÓN

Tanque de combustible

Combustible incorrecto

Tornillo de ajuste del carburador

Fuera del margen normal.

Silenciador, cilindro (lumbrera de escape)

Acumulación de carbón

Filtro de aire

Obstruido con polvo

Aletas del cilindro, cubierta de ventilador

Obstruidas con polvo

Vaciar y llenar con el combustible correcto.

Ajustar al margen normal.

Quitar

Lavar

Limpiar

Si le parece que la unidad necesita otros servicios, consulte nuestro centro de servicio en su área.

38

Page 38
Image 38
Zenoah HB2302 Troubleshooting guide, Guide de localisation des pannes, 13. Guía de localización y solución de problemas

HB2302 specifications

The Zenoah HB2302 is a high-performance handheld blower that stands out in the market for its blend of power, efficiency, and user-friendly design. Designed for both residential and commercial use, this equipment is ideal for managing yard work, clearing leaves, and maintaining outdoor spaces. The HB2302 is powered by Zenoah's advanced engine technology, offering reliable performance while minimizing emissions.

One of the standout features of the HB2302 is its lightweight construction. Weighing just 4.4 kg (9.7 lbs), the blower is easy to handle, reducing user fatigue during prolonged use. Its ergonomic design includes a padded handle that provides a comfortable grip, ensuring better control and maneuverability. These characteristics make the blower suitable for various tasks, from small garden maintenance to larger landscaping projects.

Equipped with a powerful 23.9 cc two-stroke engine, the HB2302 delivers impressive airspeed and airflow. With a maximum airspeed of 75 m/s (167 mph) and an air volume of 0.85 m³/min (30.0 cfm), it efficiently clears debris and leaves, making it an invaluable tool for seasonal clean-up. The design of the blower nozzle is optimized to improve air intake and enhance overall airflow, resulting in a more efficient clearing performance.

The HB2302 also incorporates cutting-edge engine technology such as Easy Start for hassle-free ignition. This feature minimizes the pull force required to start the engine, allowing users to get to work quickly without exhausting themselves. Additionally, the blower's fuel-efficient operation means lower fuel consumption, which is an essential consideration for both environmental impact and operational costs.

Another key characteristic of the Zenoah HB2302 is its low noise level. With a sound pressure level of 94 dB(A), it operates quietly in comparison to many gas-powered blowers, making it suitable for use in residential areas where noise restrictions may apply. This consideration ensures that users can work without disturbing the peace of their neighborhood.

Overall, the Zenoah HB2302 represents an effective blend of performance, comfort, and environmental consciousness, catering to the needs of both casual homeowners and professional landscapers. Its lightweight design, powerful engine, and user-friendly features make it an ideal choice for anyone looking to tackle outdoor cleaning tasks with ease and efficiency. Whether you’re maintaining your garden or handling larger landscaping needs, the HB2302 is designed to meet a variety of requirements.