Zephyr APN-M90ABX, APN-M90AWX Installation - External & In-Line Blower Preparation

Models: APN-M90ABX APN-M90AWX

1 20
Download 20 pages 14.01 Kb
Page 13
Image 13
Installation - External & In-Line Blower Preparation

6.Insert the 6 pin female molex connector into the junction box. See Fig. 6A. Secure remote blower junction box to top of blower housing using (2) screws. See Fig. 6B

7.Feed remote blower wire harness through remote blower junction box cover and Connect the wires with those inside the junction box. See Fig. 7

Note: Carry out the power supplly connection in accordance with the national electric

code, ANSI/NFPA 70-1999.

8.Secure cover to junction box using (2) screws.

Note1: A cable lock (not included) may be required by local codes. Please review local codes for more informa- tion.

9.Attach 6 pin male molex connectors to 6 pin fe- male molex connectors inside blower housing. See Fig. 8

Note2: Check local codes to determine minimum wire gauge.

See manual included with external and in-line blower for instructions on installing the blo- wer.

Installation - External & In-Line Blower Preparation