DV360/580 Series Direct Vent Gas Fireplace
Operating Instructions
Glass Information
Only glass approved by CFM Corporation should be used on this fireplace.
• The use of any
•Care must be taken to avoid breakage of the glass.
•Do not operate appliance with glass front re- moved, cracked or broken.
•Replacement glass (complete with gasket) is available through your CFM Corporation dealer and should only be installed by a licensed quali- fied service person.
Louvre Removal
Window Frame
Assembly
Fireplace Front
Clamps
Glass
Panel
Glass
Panel
Pull Clamp
Hook
Push Clamp
Handle FP771a
To remove louvre assembly top, pull louvre up and then lift out. The louvre assembly bottom
2.
Fig. 47 Window frame assembly removal.
ed). After the initial cleaning process the glass should be cleaned two or three times during each operating
is hinged at the bottom edge and swings down. (Fig. 46)
1.
Louvre
season depending on the environment in the house.
Clean the glass after the first two weeks of operation.
Do not clean glass when hot.
Glass Panel
FP444
Fig. 46 Remove louvre assembly top.
Window Frame Assembly Removal
1.Turn the fireplace OFF (including the pilot).
2.If the unit has been operating, allow time for the components to cool.
3.Remove louvre assembly top.
4.Open the louvre assembly bottom.
5.Release the two clamps along lower edge of the frame by pulling down on clamp handles. (Fig. 47)
6.Tilt window frame assembly out slightly at the bot- tom, lift the frame up and away from the fireplace.
7.To replace window frame assembly reverse proce- dure.
Glass Cleaning
It is necessary to clean the glass periodically. During
Do not use abrasive cleaners.
Do not strike or slam the glass.
Installation of Optional Ceramic Panels
DV360
1.Remove glass.
2.Remove glass heat shield located at the top of the firebox toward the front.
3.Place the rear panel behind the rear log bracket.
4.Slide the right and left panels into place, The right and left panels will hold the rear panel in place when positioned properly.
5.Replace the glass heat shield.
6.Place the right and left hearth refractories and bring them together in the center and slide towards the front of the unit.
Replacement of
Ceramic Hearth Panels
1.Remove glass.
2.Set left and right panels on hearth and bring towards front of unit.
24 | 20010667 |