Rear Wall Vent Installation

DV360/580 Series Direct Vent Gas Fireplace

Vent Opening for Combustible Walls

 

 

 

 

 

 

 

 

Rear Vent Top View

20” (508 mm)

 

 

 

 

Max.

 

 

 

 

 

 

 

 

 

 

 

 

DVR584-600

Fig. 20 Rear vent application, no elbows.

9³⁄

(240 mm)

10³⁄

(265 mm)

Fireplace Hearth

Framing Detail

 

20”

20”

 

(508 mm)

 

(508 mm)

 

Max.

 

Max.

 

 

45°

 

45°

Rear Vent Top View, Corner Installation

FP836

Fig. 21 Rear vent application, one 45° elbow.

Rear Wall Vent Installation

Twist Lock Pipe

Step 1

Locate and cut the vent opening in the wall.

For combustible walls first frame in opening. (Fig. 22)

NOTE: When using flex vent, the opening will have to be measured according to the 1” (25mm) rise in 24” (610mm) vertical run.

Combustible Walls: Cut a 10³⁄”H x 9³⁄” W (265 mm x 240 mm) hole through the exterior wall and frame as shown. (Fig. 22)

Noncombustible Walls: Hole opening should be 7¹⁄” (191mm) diameter.

Zero clearance sleeve is only required for combustible walls.

Step 2

Measure wall thickness and cut zero clearance sleeve parts to proper length (Maximum 12” / 305 mm). As- semble sleeve to its maximum opening (10³⁄” x 9³₈”) and attach to firestop assembly. (Fig. 23)

Step 3

Measure the horizontal length requirement for the vent- ing including a 2” (51 mm) overlap, i.e. from the elbow to the outside wall face plus 2” (51 mm). (Fig. 21)

Opening for Noncombustible Wall

7¹⁄

 

(190 mm)

 

Fireplace Hearth

VO584-100

Fig. 22 Locate vent opening on wall.

 

Adjustable Zero

Max. Length

Clearance Sleeve

12” (305 mm)

 

 

#8 Screws (2)

#8 Screws

 

(2)

 

 

#8 Screws

 

(2)

Firestop

Adjustable Zero

 

Clearance Sleeve

ZCS101

Fig. 23 Adjustable zero clearance sleeve.

 

Step 4

Install the 4” (102 mm) vent to the appliance collar and secure with 3 sheet metal screws. Install the 7” (178

mm)vent pipe to the appliance collar and secure with 3 sheet metal screws. It is not necessary to seal this con- nection. If a 45° elbow is being used attach the elbow to the appliance in the same manner then attach the venting to the elbow.

It is critical that there is no downward slope away from the appliance when con- necting the vent or elbow.

Step 5

Guide the venting through the vent hole as you place the appliance in its installed position. Guide the 4”

(102 mm) and 7” (178 mm) collar of the vent termina- tion into the outer ends of the venting. Do not force the termination. If the vent pipes do not align with the termination, remove and realign the venting at the appli- ance flue collars. (Fig. 24) Attach the termination to the wall as outlined in the instruction sheet supplied with the termination.