 Instructions for RF Comfort Control Valve

DV360/580 Series Direct Vent Gas Fireplace

Operation Instructions for RF Comfort Control Valve

The Comfort Control Valve allows remote control of temperature, fan and flame appearance.

NOTE: The antenna should hang in free air away from grounded metal.

Operation

1.

If the manual switch is in remote position, switch it to

 

LOCAL. (Fig. 60)

2.

Turn the pilotstat knob counterclockwise from OFF

 

to the PILOT position, push the knob down, and hold

 

in position. The pilot valve opens and allows gas to

 

flow to the pilot burner.

3.

Push plunger on the piezo until the pilot burner is lit.

 

When the pilot burner is lit, the LED on the control

 

will come on after approximately 40 seconds and will

 

be continuously red. When the light turns off which

Shut Off Procedure

If the manual switch is in the REMOTE position, the transmitter can shut off the main burner and fan. How- ever, the control is still on and a command from the transmitter can turn on the main burner or fan.

To shut off the system, turn the pilotstat knob clockwise to the OFF position. This action closes the main gas and safety valves. The transmitter cannot turn on the main burner or fan.

Transmitter Operation

Off Mode

In the OFF mode, the fireplace flame and fan are off, the display will show OFF and displays the room temperature. If the receiver is in REMOTE mode, the fireplace will shut off.

will be approximately 10 seconds after it has been

continuously red, the receiver/valve is fully powered.

Motor Top Cap

 

 

 

Piezo Ignitor

 

 

 

 

T

 

 

 

 

O

 

 

 

IL

 

 

 

 

P

 

 

OFF

 

 

 

 

 

 

 

N

 

 

 

 

 

O•

 

 

 

LOCAL

REMOTE

 

 

 

LED

 

 

 

 

 

 

LED

 

Pilostat

 

 

 

Plug

Local/Remote

Knob

 

 

 

 

 

 

 

Switch

 

 

 

 

Antenna

Mode

Auto

On

Off Shut Off Procedure

Countdown

Timer

Fan

FP1039

Display

Room Temperature

Set Temperature

Flame Height Level

Fan Speed Level

Countdown Timer

Low Battery

Flame

Up Increases Flame Height, Fan Speed Timer or Set Point

Down Decreases Flame, Fan Speed Timer or Set Point

FP1037

Fig. 60 Comfort control valve.

4.Release the knob. The shaft will move upward. The pilot burner should now stay burning. If the pilot burner goes out, repeat step 2.

5.Turn the knob counterclockwise to the ON position. If the manual switch is in the LOCAL position, the main burner will turn on immediately.

6.ON the initial use of a transmitter, a recognition operation is required between the receiver/valve and transmitter. Change the switch from LOCAL to REMOTE. Press the fan or flame button on the transmitter within 30 seconds. The LED will blink indicating the transmitter will now work with the re- ceiver/valve. If the switch continues in the REMOTE position, the transmitter will now control the main valve, flame modulation level and fan control.

7.If the manual switch is in the LOCAL position, the valve will be at the highest fixed pressure setting. The transmitter will control the fan only.

Fig. 61 Transmitter diagram.

On (Manual) Mode

In the ON mode, the room temperature, flame and fan levels will be shown. MANUAL will appear next to both the flame and fan icons.

When the control is in the ON mode, the flame and fan levels, and delay timer are changed with the up and down buttons. To change the flame level, press the flame button followed by an arrow key. To change the fan level, press the fan key followed by an arrow key. Pushing the arrow key once will change the level by one unit.