9b.Units with Honeywell valve:

DV360/580 Series Direct Vent Gas Fireplace

a)Using a Torx T20 or slotted screwdriver, remove and save the three pressure regulator mount- ing screws (A), pressure regulator tower (B) and diaphragm (C).

b)Ensure the rubber gasket (D) is properly posi- tioned and install the new Hi/ Lo pressure regula- tor to the valve using the new screws (E) supplied with the kit. Tighten screws securely. (Ref. torque: 25 in-lb).

c)Install the enclosed identification label (F) to the valve body where it can be easily seen.

9b.Units with Honeywell valve:

The Honeywell valve fitted to this unit is preset for LP gas. It is convertible to natural gas by the instal- lation of a color coded “conversion screw.” To insert the conversion screw, refer to the instructions and diagrams in the Honeywell Installation Instructions supplied in the conversion kit packaged with the DV360/DV580RMH unit.

10.Reassemble the fireplace in the reverse order, except for the window frame assembly. Leave this off until the unit has been checked for leaks and the gas supply line has been bled.

11.After bleeding the gas line and checking for leaks with a soap solution, replace the window frame assembly. Fire up the unit, check for flame impinge- ment on the logs, adjusting them if necessary. Check the manifold and supply pressures.

NOTE: If further assistance is required, refer to ‘Troubleshooting’ and ‘Parts List’ in this manual.