www.zephyronline.com
Installation - Internal Blower
The following instructions are for installing the internal blower. CAUTION: To reduce the risk of fire and electric shock, install this range- hood only with internal blower models
For external and in-line blower preparation please turn to page 12.
1. Remove the (7) screws securing the remote motor support bracket to the motor housing and then remove the bracket. See Fig.1
2.Insert the 6” sheet metal flange in the motor air exhaust outlet. Fig.
2A Then insert the plate (supplied with the motor) and secure all parts using the (4) screws. Fig2B
3.Secure the condenser, connected to the supplied wire, to the bracket using the (2 type B) screws. See Fig.3
4.Secure the green/yellow ground wire, connected to the wire supplied with the con- denser, using the screw on the bracket. (type A)
Fig. 4
5.Connect the plate and the motor, on the remote motor support bracket, securing it
using the (2 type B) screws. Fig. 5
- 10 -