Zephyr ASL-E48ASX, ASL-E42ASX Installation External & In-Line Blower Preparation

Models: ASL-E48ASX ASL-E42ASX

1 23
Download 23 pages 7.55 Kb
Page 12
Image 12

www.zephyronline.com

Installation - External & In-Line Blower Preparation

The following instructions are for preparing the hood for use with an ex- ternal or in-line blowers models CBE-1000 or PBN-1000A.

CAUTION: To reduce the risk of fire and electric shock, install this rangehood only with remote blowers rated maximum 6.2 A.

For internal blower instructions please turn to page 10.

1. Break out the partially pre- cut circle in the lid, located on the remote motor sup- port bracket, using a flat head screwdriver. Fig. 1

2.Remove the cover by un- doing the (3) screws. Fig. 2

3.Secure 8" round blower col- lar to top of blower housing

using (4 type B) screws. Fig.3

4. Insert the female connector into the remote motor support bracket enclosure. Fig.4

5. Pass the wires of the remote motor through the hole in the cover that was previously removed and connect them with those of the connector located in the enclosure. Fig. 5

Note: Carry out the power supplly connection in accordance with the national electric code, ANSI/NFPA 70-1999.

- 12 -

Page 12
Image 12
Zephyr ASL-E48ASX, ASL-E42ASX installation instructions Installation External & In-Line Blower Preparation