Zephyr COK-E48SX, COK-E36SX Installation - Ducting, Warning Fire Hazard, Some Ducting Options

Models: COK-E48SX COK-E42SX COK-E36SX

1 23
Download 23 pages 55.72 Kb
Page 8
Image 8
Installation - Ducting

Installation - Ducting

www.zephyronline.com

WARNING FIRE HAZARD

NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics, or garages. All exhaust must be ducted to the outside.

Use single wall rigid Metal ductwork only.

Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or DuctTape.

Some Ducting Options:

Roof Pitch w/

External

Flashing & Cap

Blower

side wall

cap with

gravity

damper

Soffit or crawl space

External

Blower

Soffit or crawl space

6

Page 8
Image 8
Zephyr COK-E48SX, COK-E36SX, COK-E42SX manual Installation - Ducting, Warning Fire Hazard, Some Ducting Options