Zephyr ZRM-E42AS Installation - Mounting Height & Clearance, Ducting, Mounting Height Ducted

Models: ZRM-E36AS ZRM-E42AS

1 19
Download 19 pages 35.83 Kb
Page 8
Image 8
Installation – Mounting Height & Clearance

www.zephyronline.com

Installation – Mounting Height & Clearance

min. ducted 28” min. recirc. 32“

max. 39”

4”

min. 28”

max. 36”

min. ducted 92” (7’8“) min. recirc. 96” (8’) max. 111” (9’3”)

36”

Note: Bottom duct covers may be cut down by 4” to expose top duct cover louver holes. This may be necessary if the customer is recirculating the hood, has an 8’ ceiling and wants the hood mounted between 29 - 32 inches above the cooking surface.

DUCTING

A minimum of 6” round or 3-1/4 x 10” rectangular GXFWPXVWEHXVHGWRPDLQWDLQPD[LPXPDLUÀRZ HI¿FLHQF\

Always use rigid type metal ducts only. Flexible GXFWVFRXOGUHVWULFWDLUÀRZE\XSWR

Use calculation worksheet to compute total duct work.

ALWAYS, when possible, reduce the number of transitions and turns. If a long duct run is required, increase duct size from 6” to 7” or 8”.

If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible.

Minimum mount height between range top to hood bottom should be no less than 28”.

Maximum mount height should be no higher than 36”.

It is important to install the hood at the proper mounting height. Hoods mounted too low could UHVXOWLQKHDWGDPDJHDQG¿UHKD]DUGZKLOHKRRGV mounted too high will be hard to reach and will ORRVHLWVSHUIRUPDQFHDQGHI¿FLHQF\

If available, also refer to range manufacturer’s height clearance requirements and recommended hood mounting height above range. Always check your local codes for any differences.

Mounting Height (Recirculating)

Minimum Ceiling Height 8’. Hood mounted 28” DERYHFRRNLQJVXUIDFH´IURPÀRRU Maximum Ceiling Height 9’3”. Hood mounted 36” DERYHFRRNLQJVXUIDFH´IURPÀRRU

Mounting Height (Ducted)

¶´+RRGPRXQWHG´DERYHFRRNLQJVXUIDFH

´IURPÀRRU

Duct cover extension kit available for ceiling heights up to 12 feet. Turn to page 16 for part number and ordering information.

DAMAGE-SHIPMENT / INSTALLATION:

Please fully inspect unit for damage before installation.

If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or replacement.

If the unit is damaged by the customer, repair or replacement is the responsibility of the

customer.

‡ ,IWKHXQLWLVGDPDJHGE\WKHLQVWDOOHU LIRWKHU WKDQWKHFXVWRPHU UHSDLURIUHSODFHPHQWPXVW be made by arrangement between customer and installer.