Zephyr ZTO-M795 manual CONTROLS FILTER CHANGE INDICATOR Carbon Filters, Filter Replace Indicator

Models: ZTO-M795

1 17
Download 17 pages 15.09 Kb
Page 12
Image 12
CONTROLS: FILTER CHANGE INDICATOR (Carbon Filters)

FEATURES & CONTROLS

9

CONTROLS: FILTER CHANGE INDICATOR (Carbon Filters)

Filter Change Reminder (Carbon, if fitted):

When your hood is installed as a 'Purifying' (Ductless Recirculating) unit, it is fitted with a set of Carbon Filters to purify exhaust and fumes from cooking, and re-circulates the air within the home. These Carbon Filters are required to be replaced after every 120 hours of use. The Filter Change Reminder function in the microprocessor needs to be switched on. The microprocessor in the controls when set, will elapsed and count

usage time and indicate by a flashing Filter Change Reminder (Carbon, if fitted):Setting the Filter Change Reminder:Filter Replace Indicator:Re-setting Function: when carbon filter replacement is needed every 120 hrs.

Setting the Filter Change Reminder:

When Off, hold Manual background for approx. 5 seconds. The display will change from Manual backgroundManual backgroundManual backgroundManual background

(exhaust mode) to Manual backgroundManual backgroundManual backgroundManual background , (purifying mode/

carbon filters used) this indicates that the elapse timer function is switched on and Carbon Filters are used.

Filter Replace Indicator:

When the display Manual backgroundManual backgroundManual backgroundManual background starts flashing, the Carbon Filters requires replacement after 120 hours of use.

Re-setting Function:

Once filters are replaced, with hood off,

press and hold Manual background , the display will appear; hold for approximately 5 seconds until Manual backgroundManual backgroundManual backgroundManual background

on display disappears

 

 

 

 

 

. The Filter

 

 

 

 

 

 

Change Reminder is now re-set and a new 120 hours elapse cycle is initiated.

Set Mode

hold 5 secs.

Change Filters

To Reset

hold 5 secs.

display from <--> to <C>

display <C> flashes

display from <C> to < >

Page 12