StudSensor™ Pro SL-AC Stud Finder
9
AC WireWarning

StudSensorPro SL-AC Stud Finder

with AC WireWarningand

SpotLite® Pointing System

WORKING WITH DIFFERENT MATERIALS

StudSensor Pro SL-AC is for use on dry, interior walls only. Although StudSensor Pro SL-AC can scan through up to

112 in. (38 mm) of common construction materials in DeepScan mode, three pri- mary factors can affect sensing depth: thickness, density, and moisture content.

StudSensor Pro SL-AC can scan effectively through most sheet materials, including:

The Zircon StudSensorPro SL-AC detects wood and metal studs and joists in walls, floors, and ceilings. It features two scanning modes, recessed LEDs, a durable high-impact case, and the patented SpotLite® Pointing System. It also has WireWarning

to continuously detect hot AC voltage in both modes.

INSTALLING THE BATTERY

1

Squeeze sides of

 

clip to help

release clip end.

2

Slide 9-V battery

 

into compartment,

terminal side first, matching (+) and (–) terminals from battery to case.

SpotLite® Pointing System

Stud Edge Groove

TruCal®

LED

StudScan

STUD SCAN

DEEPSCAN

Stud DeepScan®

 

 

Mode LED

 

 

Mode LED

On/Off Button

 

 

Mode Switch

When the top green LED is lit, a steady

tone sounds, and the SpotLite® shines, you have located the edge of the stud. Mark this spot.

Bare wood flooring (in DeepScan mode)

Linoleum on wood base

Gypsum drywall over plywood sheathing

Wallpapered walls (if dry)

Textured ceilings if uniform thickness (Place a thin piece of cardboard on ceiling and scan through it to avoid damage

to texturing.)

StudSensor Pro SL-AC is not designed to scan materials with inconsistent density such as:

Ceramic floor tile

Carpeting and padding

Wallpaper with metallic fibers

Freshly painted walls that are still damp (must dry at least a week)

Lath and plaster walls

Foil covered insulation board

FCC Part 15 Class B Registration Warning

This equipment has been tested and found to comply with the limits for a Class B digital device, pur- suant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the

equipment is operated in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with

the instructions, may cause harmful interference to radio communications. However, there is no guar- antee that

interference will not occur in a particular installation. If

this equipment does cause harmful interference to radio or television reception, which can be deter- mined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

(1)Reorient or relocate the receiving antenna.

(2)Increase the separation between the equipment and receiver.

(3)Connect the equipment into an outlet on a circuit, different from that which the receiver is connected (if applicable).

3

Replace the clip.

 

Battery will last

approximately two years under normal conditions.

CALIBRATION AND SCANNING IN STUD SCAN OR DEEPSCAN® MODES
Note: Unit calibrates on each use.

Use Stud Scan Mode for depths to about 34 in. (19 mm) and DeepScan for depths up to

112 in. (38 mm) or double layers.

Note: Keep unit flat against wall. Do not lift or tilt unit during calibration or scanning.

4

Slide the Mode Selector

 

switch to the desired

scanning mode. The mode can

be selected with the unit on

or off.

5

With StudSensor Pro SL-AC

 

turned off, position the unit

flat against the wall.

6

Without moving unit, squeeze

 

and hold On/Off button.

TruCal® LED should be lit.

7

Continue to hold

 

in the On/Off

button then slowly slide

unit horizontally across

the wall, right or left.

8

As you begin to approach a stud, the red LEDs

 

will light successively, from bottom to top.

10 Continue scanning beyond marked

spot until green LED goes out. Slide unit in reverse direction to locate other edge of stud.

11 Mark this second spot. Middle of stud

is centered between the two marks.

CONTINUOUS AC VOLTAGE DETECTION (WireWarning)

12 The StudSensor Pro SL-AC detects from 90 to 250 V at 50 to 60 Hz

AC in a hot electrical wire. The voltage detection feature works continuously in both Stud Scan and DeepScan modes. When sensing voltage, the small AC light comes on.

Caution: The StudSensor Pro SL-AC will not detect hot wires inside metal pipe or conduit, behind metallic wall covering, or behind some plywood or other dense materials. Use extra caution in these situations. Always turn the power off when nailing, cutting, or drilling near electrical wires.

OPERATING CAUTIONS

13

Depending on the proximity of electrical wiring

 

or pipes to the wall surface, the scanner may

detect them in the same manner as studs. Caution should always be used when nailing, cutting, or drilling in walls, floors, and ceilings that may contain these items.

To avoid surprises, remember that studs or joists are normally spaced 16 in. (406 mm) or 24 in. (610 mm) apart and are 112 in. (38 mm) in width. Anything closer together or a different width may not be a stud, joist, or firebreak. Always turn off the power when working near electrical wires.

(4)Consult the dealer or an experienced radio/TV technician for help.

HELPFUL HINTS

Situation

Probable Causes

Solutions

Lights start flashing and

• Scan began on dense part of

• Turn unit off, move over a few inches, press On/Off button,

unit starts beeping.

wall or over a stud.

and start again.

 

• Unit not flat against wall.

• On rough surfaces, place piece of paper on wall, scanning

 

• Unit tilted or lifted during scan.

through it to help slide unit more smoothly.

 

(All these factors affect proper

• Keep hand at least 6 in.(152 mm) from StudSensor

 

calibration.)

Pro SL-AC while you calibrate and scan. Hold unit with

 

 

thumb and index finger no higher than handgrips. Be

 

 

careful not to move your fingers after calibration.

 

 

• Always hold unit parallel to and move perpendicular to

 

 

object you’re trying to locate.

 

 

 

Center green LED doesn’t

• Wall is particularly thick or

• Interpret red LED closest to center as stud edge.

light in Stud Scan mode.

dense.

• Switch to DeepScan to locate the stud.

 

 

 

The green TruCal LED

• Unit may not be flat against

• Hold unit so two Velcrostrips on the back make

lights but, when scan-

the wall.

contact with wall.

ning, unit doesn't do

• If it is in the DeepScan mode

• Recalibrate unit in a different place and rescan area.

anything else.

(the DeepScan LED is lit), you

 

 

may have calibrated over a stud.

 

 

 

 

All three red LEDs and

• Scanning surface is too dense

• If you are using unit on a recently taped, painted, or

green LED light at the

or too wet for unit to operate.

wallpapered wall, allow time to dry and try again.

same time and unit

 

 

beeps continuously.

 

 

 

 

 

Working in DeepScan

• You may have calibrated over

• Move StudSensor Pro SL-AC over a few inches

mode and can’t detect

a stud. (The error condition is

and recalibrate.

studs.

disabled in DeepScan mode

 

 

because it is twice as sensitive

 

 

as Stud Scan.)

• Hold unit so two Velcrostrips on the back make

 

• You may be holding the unit

 

like a TV remote, aiming it at

contact with wall.

 

the wall.

 

 

 

 

Detects other objects

• Electrical wiring and metal or

• Remember that studs or joists are normally spaced 16 in.

besides studs.

plastic pipes may be near or

(406 mm) or 24 in. (610 mm) apart and are 112 in.

 

touching back surface of wall.

(38 mm) wide.

 

 

• Always turn off power when cutting, nailing, or drilling

 

 

near electrical wires.

 

 

 

You suspect electrical

• Wires may be shielded behind

• See above solution.

wires, but do not

metallic wall coverings,

• Use extra caution if the area has plywood, thick wood

detect any.

plywood shearwall or other

backing behind drywall, or thicker-than-normal walls.

 

dense material, or in conduit;

• If a switch controls an outlet, make sure it is ON for

 

StudSensor Pro SL-AC may not

detection, but turned off when working near electrical wires.

 

be able to find them.

 

 

• The wires may not be hot.

 

 

• Wires may be too deep to sense.

 

 

 

 

Area of voltage detection

• Static charge may develop on

• To narrow detection, turn unit off and on again at the edge

is too large.

drywall, spreading voltage

of where wire was detected and scan again.

 

detection as much as 12 in.

 

 

(305 mm) from each side of

 

 

an actual electrical wire.

 

 

 

 

Questions? Check our Web site at www.zircon.com and click “Support.”