LXM32M

3 Basics

 

 

3.3.4.1 I/O scanning Output

The table below shows the structure of the cyclic data for the com- mands from the master to the product. See the product manual for a description of the parameters.

Byte

Meaning

Data type

Parameter address

 

 

 

 

0 ... 7

ParCh

-

Parameter channel

 

 

 

 

8 ... 9

dmControl

INT

-

 

 

 

 

10 ... 13

RefA32

DINT

-

 

 

 

 

14 ... 17

RefB32

DINT

-

 

 

 

 

18 ... 21

Ramp_v_acc

DINT

Parameter Ramp_v_acc

 

 

 

Modbus 1556

22 ... 25

Ramp_v_dec

DINT

Parameter Ramp_v_dec

 

 

 

Modbus 1558

26 ... 29

EthOptMapOut1

DINT

Parameter EthOptMapOut1

 

 

 

Modbus 17500

30 ... 33

EthOptMapOut2

DINT

Parameter EthOptMapOut2

 

 

 

Modbus 17502

34 ... 37

EthOptMapOut3

DINT

Parameter EthOptMapOut3

 

 

 

Modbus 17504

ParCh Parameters can be read or written via "ParCh", see chapter "3.3.4.3 Parameter channel".

dmControl The word "dmControl" is used to set the operating state and the oper- ating mode.

See chapters "6.1.2 Changing the operating state" and

"6.2.2 Starting and changing an operating mode" for a detailed description of the bits.

RefA32, RefB32 The two double words "RefA32" and "RefB32" are used to set two val- ues for the operating mode. The meaning depends on the operating mode; it is described in the chapters on the individual operating modes.

Ramp_v_acc / Ramp_v_dec The double words "Ramp_v_acc" and "Ramp_v_dec" are used to set the acceleration and the deceleration. They correspond to the param- eters of the same name. See the product manual for a description.

EthOptMapOut1 ... EthOptMap- The double words EthOptMapOut1 ... EthOptMapOut3 contain select- Out3 able parameters, see chapter

"5.7.3 Setting the mapping for I/O scanning".

0198441113843, V1.01, 01.2012

Modbus-TCP module

23

Page 23