5 Commissioning

 

 

LXM32M

 

 

 

 

 

 

 

 

 

 

 

 

Parameter name

Description

Unit

Data type

Parameter address

 

HMI menu

 

Minimum value

R/W

via fieldbus

 

HMI name

 

Factory setting

Persistent

 

 

 

 

Maximum value

Expert

 

 

 

 

 

 

 

 

EthOptMapInp1

Optionally mapped input parameter 1 (drive

-

UINT16

CANopen 3044:34h

 

 

to PLC)

-

UINT16

Modbus 17512

 

 

Modbus address of parameter which is

0

UINT16

Profibus 17512

 

 

-

UINT16

CIP 168.1.52

 

 

optionally mapped to Ethernet/IP assembly

 

 

 

R/W

 

 

 

or Modbus TCP I/O scanner data (drive to

 

 

 

 

 

per.

 

 

 

PLC).

 

 

 

 

 

-

 

 

 

Changed settings become active immedi-

 

 

 

 

 

 

 

 

 

ately.

 

 

 

 

 

 

 

 

 

 

EthOptMapInp2

Optionally mapped input parameter 2 (drive

-

UINT16

CANopen 3044:35h

 

 

to PLC)

-

UINT16

Modbus 17514

 

 

Modbus address of parameter which is

0

UINT16

Profibus 17514

 

 

-

UINT16

CIP 168.1.53

 

 

optionally mapped to Ethernet/IP assembly

 

 

 

R/W

 

 

 

or Modbus TCP I/O scanner data (drive to

 

 

 

 

 

per.

 

 

 

PLC).

 

 

 

 

 

-

 

 

 

Changed settings become active immedi-

 

 

 

 

 

 

 

 

 

ately.

 

 

 

 

 

 

 

 

 

 

EthOptMapInp3

Optionally mapped input parameter 3 (drive

-

UINT16

CANopen 3044:36h

 

 

to PLC)

-

UINT16

Modbus 17516

 

 

Modbus address of parameter which is

0

UINT16

Profibus 17516

 

 

-

UINT16

CIP 168.1.54

 

 

optionally mapped to Ethernet/IP assembly

 

 

 

R/W

 

 

 

or Modbus TCP I/O scanner data (drive to

 

 

 

 

 

per.

 

 

 

PLC).

 

 

 

 

 

-

 

 

 

Changed settings become active immedi-

 

 

 

 

 

 

 

 

 

ately.

 

 

 

 

 

 

 

 

 

 

EthOptMapOut1

Optionally mapped output parameter 1 (PLC

-

UINT16

CANopen 3044:2Eh

 

 

to drive)

-

UINT16

Modbus 17500

 

 

Modbus address of parameter which is

0

UINT16

Profibus 17500

 

 

-

UINT16

CIP 168.1.46

 

 

optionally mapped to Ethernet/IP assembly

 

 

 

R/W

 

 

 

or Modbus TCP I/O scanner data (PLC to

 

 

 

 

 

per.

 

 

 

drive).

 

 

 

 

 

-

 

 

 

Changed settings become active immedi-

 

 

 

 

 

 

 

 

 

ately.

 

 

 

 

 

 

 

 

 

 

EthOptMapOut2

Optionally mapped output parameter 2 (PLC

-

UINT16

CANopen 3044:2Fh

 

 

to drive)

-

UINT16

Modbus 17502

 

 

Modbus address of parameter which is

0

UINT16

Profibus 17502

 

 

-

UINT16

CIP 168.1.47

 

 

optionally mapped to Ethernet/IP assembly

 

 

 

R/W

 

 

 

or Modbus TCP I/O scanner data (PLC to

 

 

 

 

 

per.

 

 

 

drive).

 

 

 

 

 

-

 

 

 

Changed settings become active immedi-

 

 

 

 

 

 

 

 

 

ately.

 

 

 

 

 

 

 

 

 

 

EthOptMapOut3

Optionally mapped output parameter 3 (PLC

-

UINT16

CANopen 3044:30h

 

 

to drive)

-

UINT16

Modbus 17504

 

 

Modbus address of parameter which is

0

UINT16

Profibus 17504

 

 

-

UINT16

CIP 168.1.48

 

 

optionally mapped to Ethernet/IP assembly

 

 

 

R/W

 

 

 

or Modbus TCP I/O scanner data (PLC to

 

 

 

 

 

per.

 

01.2012

 

drive).

 

 

 

 

-

 

 

 

 

 

 

Changed settings become active immedi-

 

 

 

 

 

 

 

 

 

ately.

 

 

 

0198441113843, V1.01,

 

 

 

 

 

 

 

 

 

 

48

Modbus-TCP module

Page 48