LXM32M

6 Operation

 

 

6.2.6Operating mode Profile Torque

Starting the operating mode The operating mode is set and started in the process data channel with the transmit data (master to slave).

dmControl

Reference value RefA32

Reference value RefB32

Bits 0 ... 6

 

 

MODE+ACTION

 

 

 

 

 

24h

As PTtq_target

As RAMP_tq_slope

Status information The word "driveStat" provides information on the operating mode.

Bit

Name

Meaning

 

 

 

13

X_ADD1

0: Target torque not reached

 

 

1: Target torque reached

 

 

 

14

X_END

0: Operating mode started

 

 

1: Operating mode terminated

 

 

 

15

X_ERR

0: No error

 

 

1: Error

 

 

 

Terminating the operating mode The operating mode is terminated when the motor is at a standstill and one of the following conditions is met:

Stop caused by "Halt" or "Quick Stop"

Stop caused by an error

0198441113843, V1.01, 01.2012

Modbus-TCP module

59

Page 59
Image 59
Schneider Electric LXM32M manual Operating mode Profile Torque, 24 h