Reference: Remote Commands ~ Command Description

:SENSe:ANALysis:GR253A:PATH:NEAR

This query returns the value of the specified Near-End Path parameter from GR-253 analysis of received data. Ratios are returned as NR3 values, other parameters as NR1 values.

Syntax: :SENSe<slot>:ANALysis:GR253A:PATH:NEAR? <Enum>

Parameters

CV_C

CV_R

BBE_C

BBE_R

ES_C

ES_R

SES_C

SES_R

ESA_C

ESA_R

ESB_C

ESB_R

CSES_C

UAS_C

UAS_R

Description

CV Count

CV Count ratio Background block errors Background block error ratio Errored seconds

Errored second ratio Severely errored seconds Severely errored second ratio Errored seconds type A Errored second type A ratio Errored seconds type B Errored second type B ratio Consecutive SES periods Unavailable seconds Unavailable seconds error ratio

:SENSe:ANALysis:GR253A:PATH:NEAR:ALL

This query returns the values of all of the Near-End Path parameters from GR-253 analysis of received data. Ratios are returned as NR3 values, other parameters as NR1 values. The parameters are returned in the order in which they are listed under :SENSe:ANALysis:GR253A:PATH:NEAR.

Syntax: :SENSe<slot>:ANALysis:GR253A:PATH:NEAR:ALL?

3-22

OTS9100 User Manual

Page 153
Image 153
Tektronix 071-0855-05 user manual SENSeANALysisGR253APATHNEARALL