Reference: Remote Commands ~ Command Description

:SOURce:DATA:POH:DEFAult

This command sets all bytes in the generated STS-1 #1 Path Overhead data to their default values. Syntax :SOURce<slot>:DATA:POH:DEFAult

:SOURce:DATA:RATE

This query returns the output signal rate generated by the OTS transmitter.

Syntax :SOURce<slot>:DATA:RATE?

Parameters

Description

G10A

10 Gb/s (OC-192 or STM-64)

:SOURce:DATA:SECTion:TRACe

This command sets the data sequence length and data byte values transmitted in the Section Trace (J0) byte of the Transport Overhead. The data bytes are formatted as a standard IEEE-488 data block. The query form returns the current settings.

Syntax :SOURce<slot>:DATA:SECTion:TRACe? :SOURce<slot>:DATA:SECTion:TRACe <Enum> ,<Block>

Parameters

Description

L1B

Constant 8-bit data

L16B

A repeating sequence of 16 bytes, 0-filled with CRC

L16FREE

A repeating sequence of 16 bytes, arbitrary format

L64B

A repeating sequence of 64 bytes, space-filled with CR/LF

L64FREE

A repeating sequence of 64 bytes, arbitrary format

:SOURce:DATA:SECTion:TRACe:TYPE

This command sets the data sequence length transmitted in the Section Trace (J0) byte of the Transport Overhead. The query form returns the current setting.

Syntax :SOURce<slot>:DATA:SECTion:TRACe:TYPE? :SOURce<slot>:DATA:SECTion:TRACe:TYPE <Enum>

Parameters

Description

L1B

Constant 8-bit data

L16B

A repeating sequence of 16 bytes, 0-filled with CRC

L16FREE

A repeating sequence of 16 bytes, arbitrary format

L64B

A repeating sequence of 64 bytes, space-filled with CR/LF

L64FREE

A repeating sequence of 64 bytes, arbitrary format

OTS9100 User Manual

3-55

Page 186
Image 186
Tektronix 071-0855-05 user manual SOURceDATAPOHDEFAult, SOURceDATARATE, SOURceDATASECTionTRACeTYPE