Reference: Remote Commands ~ Command Description

:SENSe:ANALysis:SECTion:TRACe:EXPEcted:VALUe

This command sets the data byte values used by the receiver for Trace Identifier Mismatch measurements. The data bytes are formatted as a standard IEEE-488 data block. These values may also be set by the :SENSe:ANALysis:SECTion:TRACe:EXPEcted command. The query form returns the current values.

Syntax :SENSe<slot>:ANALysis:SECTion:TRACe:EXPEcted:VALUe? :SENSe<slot>:ANALysis:SECTion:TRACe:EXPEcted:VALUe <Block>

:SENSe:ANALysis:SECTion:TRACe:EXPEcted:VALUe:STRIng

This command sets the data byte values used by the receiver for Trace Identifier Mismatch measurements. The byte values are formatted as an ASCII string. These values may also be set by the :SENSe:ANALysis:SECTion:TRACe:EXPEcted command. The query form returns the current values.

Syntax :SENSe<slot>:ANALysis:SECTion:TRACe:EXPEcted:VALUe:STRIng? :SENSe<slot>:ANALysis:SECTion:TRACe:EXPEcted:VALUe:STRIng <String>

:SENSe:ANALysis:SECTion:TRACe:TIM

This command enables or disables the inclusion of Trace Identifier Mismatch errors in the analysis of received signals. The query form returns the current setting.

Syntax :SENSe<slot>:ANALysis:SECTion:TRACe:TIM? :SENSe<slot>:ANALysis:SECTion:TRACe:TIM <Boolean>

:SENSe:DATA:AUTOscan:STRUcture

This query returns the signal structure found in the received signal.

Syntax :SENSe<slot>:DATA:AUTOscan:STRUcture?

Parameters

Description

192

Bulk data at 10Gb/s

48

Bulk data at 2.5Gb/s

12

Bulk data at 622Mb/s

3

Bulk data at 155Mb/s

1

Bulk data at 51Mb/s

0

Mixed signal structure

OTS9100 User Manual

3-27

Page 158
Image 158
Tektronix 071-0855-05 user manual SENSeANALysisSECTionTRACeEXPEctedVALUeSTRIng, SENSeANALysisSECTionTRACeTIM