3.Do not exceed the recommended amounts of chemicals—follow the directions on the label.

4.Keep all chemicals out of the reach of children and pets.

5.Keep all containers closed tightly when not in use.

6.Never add water to the chemicals—always add the chemicals to the water as directed.

7.Always store chemicals in a cool, dry place.

MAINTAINING THE PROPER PH BALANCE

The pH factor is a measure of the relative acidity or alkalinity in the water, and is measured on a scale of 1 to 14. Pure water has a value of 7, which is neutral. Any value above 7 is alkaline, and any value below 7 is acidic. You should maintain a slightly alkaline pH level, between 7.2 and 7.8, in the hydrotherapy spa.

Severe problems can occur when the pH balance is not maintained within this range. If the pH level exceeds 7.8, dissolved minerals can build up and clog the plumbing in the spa jet unit. If the pH level falls below 7.2, the acid level in the water will begin to cor- rode the metal parts in the spa jet unit. Also, the sani- tation agents in the water will not be effective if the pH level is not properly maintained. Damage caused by improper pH levels is not covered under the warranty.

To maintain the proper pH level, test the pH of the water regularly. To test the water, purchase a pH test kit at a pool and spa supply store. The pH reading should be between 7.2 and 7.8. If the level is too low, add a pH increaser (usually soda ash). If the level is too high, add a pH reducer (usually sodium bisulfate). Test the water again after five minutes. See the instructions with your pH test kit for additional infor- mation about testing and adjusting the pH.

SANITIZING THE HYDROTHERAPY SPA

The most common sanitizing agent is a solid bromine concentrate. The amount required varies according to several factors, such as user load, temperature, and water conditions. Proper water maintenance is a com- plex process. Contact your local pool and spa supplier for information concerning which chemicals you should use in your area to sanitize the spa.

CHANGING THE FILTER CYCLE

The spa will filter the water every 12 hours. The dura- tion of the cycle can be adjusted to last 2 to 5 hours. Press the temperature up or temperature down button on the console. When the display begins to flash, press the pump button. The display will read F2. To change the time, press the temp up button until the

desired time is reached. Press the pump button to confirm the selection. As spa usage increases, the duration of the filter cycle may need to be increased.

ATTACHING AND REMOVING THE ACCESS PANEL

Turn off the spa power. To remove the indicated Access Panel (25), Remove the four 1/4” x 1 1/2” Machine Screws (46) that secure the Access Panel to the spa. Carefully remove the Access Panel and set it aside.

46

 

25

46

 

To replace the Access Panel, hold the Access Panel in place and secure it with the 4 1/4” x 1 1/2” Machine Screws (46). Be careful not to overtighten the

Screws.

DRAINING THE HYDROTHERAPY SPA

The hydrotherapy spa should be drained at least four times per year and refilled with clean water. You may need to drain the spa more often, depending on the user load. This must be done because after repeated chemical treatment the water becomes chemically saturated. Once this happens, additional chemical treatment of the water is no longer effective. The spa should also be drained if you will not be using it for long periods of time. The spa must always be drained before major repairs are made.

The hydrotherapy spa should always be covered when it is empty. Direct sunlight can cause exten- sive damage. The surface of the spa shell can reach temperatures as high as 150°F in a matter of minutes if exposed to the sun while it is empty. These high temperatures can cause significant damage, such as blistering of the shell surface and warping of the spa shell. Any damage caused by sun exposure is not covered under warranty.

14

Image 14
Contents Model No. IMSB73920 IMSG73920 Serial No Customer HOT LineTable of Contents Posting the Warning SignImportant Safety Instructions Read and Follow ALL InstructionsPage Page Before You Begin Choosing a Location for the Hydrotherapy Spa If you set up the hydrotherapy spa insideIf you set up the hydrotherapy spa outside Assembly Not shown. Do not overfill the spa Testing and Treating the Water Using the Hydrotherapy SpaWiring the Hydrotherapy SPA Starting the Hydrotherapy SPASpa Shell Diagram Using the Controls Maintenance Sanitizing the Hydrotherapy SPA Attaching and Removing the Access PanelMaintaining the Proper PH Balance Changing the Filter CycleDraining the Pumps Replacing the Light BulbTroubleshooting Symptom the Water Level Drops Part List-Model No. IMSB73920/IMSG73920 R0602A Key No. Qty DescriptionExploded Drawing-Model No. IMSB73920/IMSG73920 R0602A Icon Health & FITNESS, INC., 1500 S W., LOGAN, UT Ordering Replacement PartsLimited Warranty

IMSB73920, IMSG73920 specifications

The Image IMSG73920 and IMSB73920 are advanced imaging technologies that offer a plethora of features and capabilities, making them essential tools in various fields such as medical imaging, industrial inspection, and scientific research. These images are capturing significant attention due to their exceptional qualities and cutting-edge technologies.

One of the standout features of the IMSG73920 and IMSB73920 is their remarkable resolution. Equipped with high pixel density, these images provide incredibly detailed visuals, allowing for precise analysis and interpretation. This feature is particularly beneficial in applications like medical diagnostics, where clarity can significantly influence outcomes. The images can reveal minute structures and subtle changes that are crucial for accurate assessments.

In addition to high resolution, these imaging technologies employ advanced sensor technology. The sensors are designed to optimize light capture, improving the quality of images in varied lighting conditions. This capability enables users to capture clear images even in low-light environments, which is essential for applications such as nighttime surveillance or inspections in confined spaces.

Another key characteristic is the incorporation of sophisticated image processing algorithms. These algorithms enhance image clarity and reduce noise, ensuring that the captured visuals are both sharp and realistic. This post-processing feature is particularly useful in scientific research, where accurate data representation is critical for analysis.

Furthermore, the IMSG73920 and IMSB73920 leverage state-of-the-art connectivity options for seamless data transfer. They often come equipped with various communication interfaces, including USB, Ethernet, and wireless options, enabling easy integration with other systems and devices. This functionality supports real-time data sharing and enhances workflow efficiency.

Durability is yet another highlight of these imaging systems. Built with robust materials and designed to withstand harsh environmental conditions, they are ideal for industrial applications where equipment is often exposed to extreme temperatures, moisture, and dust. Their reliability ensures long-term use, reducing the need for frequent replacements or repairs.

Additionally, user-friendly interfaces and customizable settings make these imaging technologies accessible to a broad range of users. This versatility allows professionals from different backgrounds to harness the power of high-quality imaging without requiring extensive technical training.

In summary, the Image IMSG73920 and IMSB73920 stand out due to their high resolution, advanced sensor technology, sophisticated image processing, versatile connectivity, durability, and user-friendly design. These features make them indispensable in various sectors, enhancing the capabilities of professionals who rely on high-quality imaging for their work.