Image IMSB73920, IMSG73920 user manual Draining the Pumps, Replacing the Light Bulb

Page 15

To drain the hydrotherapy spa, follow the steps below: WINTER USE AND CARE

1.Using the console, adjust the temperature to the lowest setting.

2.Shut off the power to the spa, at the circuit breaker or GFCI.

3.Remove the access panel from the spa (see

ATTACHING AND REMOVING THE ACCESS PANEL on page 14).

4.Pull the hose out and hold it above the waterline. Remove the cap, open the valve knob, and attach a garden hose to the drain hose. Lower the hose and drain the spa.

Cap

Valve

Drain

 

Hose

 

Knob

 

 

5.When the spa is empty, remove the garden hose, close the valve knob, and re-attach the cap and return the drain hose inside the spa.

6.Re-attach the access panel.

7.Refill the spa and treat the water with chemicals (see pages 10 and 14).

DRAINING THE PUMPS

After the hydrotherapy spa is drained, the jet pumps should also be drained if the spa will be stored for more than thirty days or if it may be exposed to freez- ing temperatures.

Turn off the power to

 

the spa. To drain the jet

 

pumps, remove the

 

access panel from the

 

spa unit (see ATTACH-

 

ING AND REMOVING

Collar

THE ACCESS PANEL

 

on page 14). Locate

 

the jet pumps inside

 

the spa. Loosen the

 

indicated collar on each of the pumps.

 

The hydrotherapy spa is designed for year-round use. If you decide to store the spa for the winter, store it in a warm, dry location. Follow the steps below to winter- ize the spa.

1.Make sure the power to the spa is turned off.

2.Drain the spa (see DRAINING THE HYDROTHER- APY SPA on the previous page and this page).

3.Remove all remaining water from the spa shell. Dry the spa shell with towels.

4.Set the air controls to the lowest setting. Use a wet/dry vacuum to pull any remaining water from the system. To do this, place the vacuum nozzle over each jet, starting with the highest jet and fin- ishing with the lowest jet.

5.Set the air controls to the highest setting and repeat step 3.

6.Drain the pumps (see DRAINING THE PUMPS on this page). Once the water is drained from the pumps, place the vacuum nozzle over the drainage hole in the pumps and vacuum any additional water from the pumps. Note: For additional pro- tection, remove the pumps/motors from the spa and store them in a climate-controlled room.

7.Clean the spa shell (see page 13).

8.Clean the filter (see page 13).

9.Shut the power off at the breaker. Label the breaker in such a way that the breaker will not be turned on accidentally.

10. Re-attach the access panel and the spa cover.

REPLACING THE LIGHT BULB

If the underwater light burns out, you will need to remove the access panel to replace it (see ATTACHING AND REMOVING THE ACCESS PANEL on page 14). Make sure the spa power is turned off. Next, locate the light housing. Turn the light housing counterclockwise and remove it from the spa shell.

Light Housing

Light

 

Bulb

Light

Housing

To replace the light bulb, pull the old light bulb out of the housing and insert a new light bulb. Re-attach the light housing to the spa shell. Re-attach the access panel to the spa.

15

Image 15
Contents Customer HOT Line Model No. IMSB73920 IMSG73920 Serial NoPosting the Warning Sign Table of ContentsRead and Follow ALL Instructions Important Safety InstructionsPage Page Before You Begin If you set up the hydrotherapy spa inside If you set up the hydrotherapy spa outsideChoosing a Location for the Hydrotherapy Spa Assembly Not shown. Do not overfill the spa Starting the Hydrotherapy SPA Using the Hydrotherapy SpaWiring the Hydrotherapy SPA Testing and Treating the WaterSpa Shell Diagram Using the Controls Maintenance Changing the Filter Cycle Attaching and Removing the Access PanelMaintaining the Proper PH Balance Sanitizing the Hydrotherapy SPAReplacing the Light Bulb Draining the PumpsTroubleshooting Symptom the Water Level Drops Key No. Qty Description Part List-Model No. IMSB73920/IMSG73920 R0602AExploded Drawing-Model No. IMSB73920/IMSG73920 R0602A Ordering Replacement Parts Limited WarrantyIcon Health & FITNESS, INC., 1500 S W., LOGAN, UT

IMSB73920, IMSG73920 specifications

The Image IMSG73920 and IMSB73920 are advanced imaging technologies that offer a plethora of features and capabilities, making them essential tools in various fields such as medical imaging, industrial inspection, and scientific research. These images are capturing significant attention due to their exceptional qualities and cutting-edge technologies.

One of the standout features of the IMSG73920 and IMSB73920 is their remarkable resolution. Equipped with high pixel density, these images provide incredibly detailed visuals, allowing for precise analysis and interpretation. This feature is particularly beneficial in applications like medical diagnostics, where clarity can significantly influence outcomes. The images can reveal minute structures and subtle changes that are crucial for accurate assessments.

In addition to high resolution, these imaging technologies employ advanced sensor technology. The sensors are designed to optimize light capture, improving the quality of images in varied lighting conditions. This capability enables users to capture clear images even in low-light environments, which is essential for applications such as nighttime surveillance or inspections in confined spaces.

Another key characteristic is the incorporation of sophisticated image processing algorithms. These algorithms enhance image clarity and reduce noise, ensuring that the captured visuals are both sharp and realistic. This post-processing feature is particularly useful in scientific research, where accurate data representation is critical for analysis.

Furthermore, the IMSG73920 and IMSB73920 leverage state-of-the-art connectivity options for seamless data transfer. They often come equipped with various communication interfaces, including USB, Ethernet, and wireless options, enabling easy integration with other systems and devices. This functionality supports real-time data sharing and enhances workflow efficiency.

Durability is yet another highlight of these imaging systems. Built with robust materials and designed to withstand harsh environmental conditions, they are ideal for industrial applications where equipment is often exposed to extreme temperatures, moisture, and dust. Their reliability ensures long-term use, reducing the need for frequent replacements or repairs.

Additionally, user-friendly interfaces and customizable settings make these imaging technologies accessible to a broad range of users. This versatility allows professionals from different backgrounds to harness the power of high-quality imaging without requiring extensive technical training.

In summary, the Image IMSG73920 and IMSB73920 stand out due to their high resolution, advanced sensor technology, sophisticated image processing, versatile connectivity, durability, and user-friendly design. These features make them indispensable in various sectors, enhancing the capabilities of professionals who rely on high-quality imaging for their work.