The spa jet unit features an automatic filter cycle and

 

DRAINING THE PUMP

freeze protection. If the spa jet unit has not been

 

 

operated for three hours, the pump will begin circulat-

 

After the spa is drained (see DRAINING THE SPA

ing the water for twenty minutes to filter any impuri-

 

above), the pump in the dry side jet pack should also

ties. Also, if the water temperature falls below 40°F,

 

be drained if the spa will be stored for more than thirty

the pump will begin circulating and heating the water

 

days, or if it may be exposed to freezing tempera-

to prevent the water from freezing.

 

tures. To drain the pump, follow these steps:

DRAINING THE SPA

 

• Remove the pillow from the wet side jet pack

 

 

 

• Unscrew the two threaded collars (see assembly

To drain the spa, you must use a garden hose to

 

step 4) connecting the dry side jet pack to the wet

siphon the water. Place one end of the hose in the

 

side.

spa and hold it in front of a hydrotherapy jet until

 

• Remove the filter cap

there is a flow of water coming out of the hose.

Turn

• Remove the six screws securing the Dry Side Shell

off the spa unit and unplug the power cord. The

 

(15) to the dry side jet pack.

unit will be damaged if it is run without water cir-

 

• Locate the pump inside the spa jet unit.

culating.

Be sure the end of the hose in the spa is on

 

• The nut on one side of the pump must be

the floor of

the spa.

 

unscrewed and the unit must be tipped on its side

• Rock the spa jet unit slightly, until all the water has drained from the pump.

• Replace the nut on the pump

• Replace the dry side shell, filter cap and pillow

USING THE CONSOLE

Refer to the console diagram at the right. The function of each console control is explained below:

Thermostat: Controls the temperature of the water. The thermostat can be set to heat the water from 70°F to 104°F. Use a medical or other accurate ther- mometer to check the temperature of the water.

On/Off Button: Turns the spa jet unit on and off and changes the operation mode of the spa. The spa has

three modes of operation:

Auto Heat

Soak

Hydrotherapy

When your spa is in the auto heat mode, pushing the button once will cause it to go into soak mode for 20 minutes. Pushing the button twice will cause the spa

to go into hydrotherapy mode (the jets will be running) for 20 minutes. If your spa is not heating, pushing the button once will cause it to go into hydrotherapy

mode. Pushing the button again will switch to soak mode.

The spa jet unit also features an automatic mode, which heats and filters the water when the spa is left unattended. When the spa jet unit is first plugged in, or if the on/off button on the console has not been pressed for longer than three hours, the automatic

Thermostat

On/Off Button

mode will begin filtering or heating the water, as need-

ed. Note: To keep the filter and heat cycles from running, the power cord must be unplugged.

The On/Off button has a built-in delay factor. The spa will turn on 5 to 10 seconds after the button is pressed.

12

Image 12
Contents Model No Serial No Customer HOT LineExcluding holidays Sears CANADA, INC., TORONTO, Ontario M5B 2B8Table of Contents Important Safety Instructions Keep all chemicals away from children and petsSee Priming the SPA JET Unit on Using the spa Has been repaired or replaced by a qualified electricianNever use the spa alone Keep pets away from the spa at all timesBefore You Begin If you set up the spa inside If you set up the spa outsideChoosing a Location for the Hydrotherapy Spa An extension cord cannot be used with the spaAssembly CrossSection Pushed fully through the vinyl liner Drawing 4ALine. Do not overfill the spa Using the Hydrotherapy Spa Testing and Treating the WaterPriming the SPA JET Unit Plugging in the SPAHeating System of Your SPA SPA JET Unit OperationSecuring the SPA Cover ImporUsing the Console Draining the PumpDraining the SPA TurnMaintenance Trouble-shooting Symptom the SPA will not OperateSymptom the Pump Hums Symptom the Water Pulsates or There is Minimum Water FlowSymptom the Water is not Being Cleaned by the Filter Symptom the Water Level DropsSymptom the SPA Pump Loses ITS Prime Be kept outdoors in cold weather, you mustPage Page Customer Record Model NoLimited 90 Day Spa Warranty Ordering Replacement Parts Model Number of the product Name of the product ImageIs a registered trademark of Icon Health & Fitness, Inc Part No R1199ACleaning and Maintaining the Spa Customer ServiceChoosing a Location for the Spa Plugging in the SpaQty Lit Pack Qty831.108150