Image IMHS45590 manual Trouble-shooting

Page 16

Trouble-shooting

Most problems can be solved by following the simple steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time.

1.SYMPTOM: THE SPA WILL NOT OPERATE

a.Check to see if the GFCI breaker is tripped or was not turned on. Reset the GFCI breaker.

2.SYMPTOM: THE CIRCUIT BREAKER OR THE GFCI TRIPS WHILE THE SPA IS OPERATING

a.Reset the circuit breaker or the GFCI. If the cir- cuit breaker or the GFCI trips again, contact a qualified electrician for service.

3.SYMPTOM: THE PUMP HUMS

a.The filter may be dirty or damaged. Remove the filter from the filter housing and clean or replace the filter (see page 13).

b.The pump may have a foreign object stuck in the impeller. Contact our customer service department.

c.The pump may have a loose wire connection. Contact our customer service department.

4.SYMPTOM: THE PUMP HUMS, BUT DOES NOT ROTATE

a.The pump may be jammed. Contact our cus- tomer service department. If your spa is no longer under warranty, contact a local spa and pool service provider.

5.SYMPTOM: THE PUMP IS NOISY WHILE OPERATING

a.There may be debris in the pump. Contact our customer service department.

b.The pump may have a bad bearing. Contact our customer service department.

6.SYMPTOM: THE WATER DOES NOT HEAT

a.Make sure that the hydrotherapy spa is fully covered with the spa cover. The spa cover must be tight for the water to heat. Set the air control to low. The water will heat at a rate of 1.8¡F per hour. If you are using the spa indoors and the room temperature is main-

tained at 70¡F, it will take approximately 24 to 36 hours for the water to reach the set temper- ature.

b. If you are using the hydrotherapy spa outdoors, it may take longer for the water to heat. See the chart below for the approximate heating time.

Air TemperatureHeating Time

70¡F +

16 to 24 hours

50¡FÐ70¡F

1 to 2 days

30¡FÐ50¡F

2 to 4 days

b. If the water still has not heated after four days, contact our customer service department.

7.SYMPTOM: THE WATER IS NOT BEING CLEANED BY THE FILTER

a.Check to see if the filter is in place. Clean the filter if it is dirty.

b.Check the chemical balance of the water. If the pH is incorrect, the sanitizing agents will not function properly.

8.SYMPTOM: THE WATER PULSATES OR THERE IS MINIMUM WATER FLOW

a.This usually occurs only when the water level is low. Add water until the jets are covered (see step 3 on page 9).

9.SYMPTOM: THE WATER LEVEL DROPS

a.Some water loss due to evaporation is normal. If rapid water loss occurs, or if you notice wet- ness on the floor around the hydrotherapy spa, the spa shell may have a leak. Contact your local pool and spa service provider for repairs.

b.A clamp or seal inside the pump compartment may be loose. Check inside the pump compart- ment for excess water and watch the pump unit while it is operating to see if water drips from any of the plumbing. If you can identify the location of the leak inside the spa jet unit, tight- en the clamp or replace the damaged seal.

16

Image 16
Contents Model No. IMHS45590 Serial No Customer HOT LineTable of Contents Posting the Warning SignImportant Safety Instructions Read and Follow ALL InstructionsPage Page Before You Begin If you set up the hydrotherapy spa inside If you set up the hydrotherapy spa outsideChoosing a Location for the Hydrotherapy Spa Do not use an extension cord with the hydrotherapy spaAssembly Page Using the Hydrotherapy Spa Testing and Treating the WaterPlugging in the Hydrotherapy SPA Starting the Hydrotherapy SPASpa Shell Diagram Securing the SPA Cover on the SPAUsing the Controls Maintenance Attaching and Removing the Access Panel Water ChemistryMaintaining the Proper PH Balance Draining the Hydrotherapy SPADraining the Pump Replacing the Light BulbTrouble-shooting Symptom the Console Displays ONE Symptom the Console Displays the Words Òcooló or ÒiceóÒilocó Part ListÑModel No. IMHS45590 Key No. Qty DescriptionExploded DrawingÑModel No. IMHS45590 Limited Warranty Ordering Replacement PartsIcon Health & FITNESS, INC., 1500 S W., LOGAN, UT