Page 10

Using the Hydrotherapy Spa

The hydrotherapy spa is designed to seat six adults. The spa holds 300 gallons of water and offers a heat- ing system (80°F to 104°F), a filtration system, and adjustable hydrotherapy jets. Follow the guidelines below to use and maintain the spa for your long-term enjoyment.

WIRING THE HYDROTHERAPY SPA

The hydrotherapy spa is designed to operate with a 240-volt power source. It must be wired directly into a grounded circuit with a Ground Fault Circuit Interrupter (GFCI) capable of carrying 30 amps. No other appliance should be on the same circuit.

Connection of the spa to the 240-volt power source must be performed by a qualified, licensed electrician and must comply with all local, state, and federal electrical codes. The qualified, licensed electrician can refer to the instructions on the inside of the electronics package for information about con- necting the spa to a 240-volt power source.

Once the spa is filled with water, the power can be turned on. Note: The first time the power is turned on, the spa will start automatically.

TESTING AND TREATING THE WATER

The first time you use the spa, you should test and

Once you have tested the GFCI, you should verify the water flow from the pumping unit. Set the air control on the console to the lowest setting (see USING THE CONTROLS on page 12). The pumping unit will heat the water as it pumps. Cover the hydrotherapy spa with the spa cover. The spa cover must be tight (see SECURING THE SPA COVER ON THE SPA on this page). The water will heat at about 6°F per hour with the cover on. If you are using the spa indoors, and the room temperature is maintained at 70°F, it will take approximately 6 to 8 hours for the water to reach the set temperature.

The temperature and the water flow can be set or changed with the controls on the console (see USING THE CONTROLS on page 12).

SECURING THE SPA COVER ON THE SPA

To secure the spa cover, snap the latches on the spa

cover into the buckles on the Latch cedar panels.

To lock the buckles, insert

the key and turn it clock- Key wise 1/4 turn. To unlock the buckles, insert the key and

turn it counterclockwise 1/4

treat the water. You must also treat the water each time you refill the spa. A test strip and a chemical

turn. Always keep the buckles locked when the

Buckle

pack are available at your local pool and spa supplier. Follow the directions carefully on the chemical pack to test and treat the water. Always keep the chemicals away from children and pets.

See WATER CHEMISTRY on page 14 for information concerning proper water maintenance.

STARTING THE HYDROTHERAPY SPA

You should always test the GFCI before using the hydrotherapy spa. First, turn on the spa by pressing the jet button on the console (see USING THE CON- TROLS on page 12). Once the spa is running, press the GFCI “test” button. The spa should shut off. Press the “reset” button. The spa should resume normal operation. If the spa continues to run after the “test” button is pressed, the GFCI is damaged. Do not use the spa until the GFCI has been repaired or replaced by a qualified electrician.

spa is not in use. Keep the keys in a safe place, out of the reach of children.

10

Image 10
Contents Model No. IMSB61610 IMSG61610 Serial No Customer HOT LineTable of Contents Posting the Warning SignImportant Safety Instructions Read and Follow ALL InstructionsPage Page Before You Begin If you set up the hydrotherapy spa outside If you set up the hydrotherapy spa insideChoosing a Location for the Hydrotherapy Spa Assembly Have to be drained before it can be moved Clean. Before filling the spa, make sure that it isMolded fill line. Do not overfill the spa Testing and Treating the Water Using the Hydrotherapy SpaWiring the Hydrotherapy SPA Securing the SPA Cover on the SPASpa Shell Diagram Using the Controls Maintenance Maintaining the Proper PH Balance Attaching and Removing Access PanelsWater Chemistry Changing the Filter CycleDraining the Pump Replacing the Light BulbTrouble-shooting Symptom the Console Displays the Words Cool or ICE Symptom the Console Displays ONEPart List-Model No. IMSB61600/IMSG61600 Key No. Qty DescriptionExploded Drawing-Model No. IMSB61600/IMSG61600 R1201A Limited Warranty Ordering Replacement PartsIcon Health & FITNESS, INC., 1500 S W., LOGAN, UT