Porter-Cable DBSI325 Safety Guidelines / Definitions, Important Safety Instructions, Be used

Page 3

SAFETY GUIDELINES / DEFINITIONS

This manual contains information that is important for you to know and understand. This infor- mation relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these sections.

indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

indicates a potentially hazardous situation which, if not avoided,may result in minor or moderate injury

used without the safety alert symbol indicates potentially hazardous situation which, if not avoided, may result in property damage.

IMPORTANT SAFETY INSTRUCTIONS

Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and

operating instructions before using.

RISK OF ELECTROCUTION AND FIRE

HAZARD

WHAT CAN HAPPEN

HOW TO PREVENT IT

 

 

 

Attempting to

Back feeding electricity through

Never backfeed electricity

connect generator

a building’s electrical system to

through a structure's electrical

directly to the

the outside utility feed lines

system.

electrical system

could endanger repair persons

 

of any building

attempting to restore service.

 

structure.

 

 

Attempting to connect to the in-

To connect to a structure's electri-

 

 

coming utility service could result

cal system in a safe manner,

 

in electrocution.

always have a Double-Throw

 

 

Transfer Switch installed by a

 

Restoration of electrical service

qualified electrician and in compli-

 

while the generator is connected

ance with local ordinances.

 

to the incoming utility could

(When installing a Double-

 

result in a fire or serious damage

Throw Transfer Switch, a mini-

 

if an isolator switch is not

mum of 10 gauge wiring must

 

installed.

be used.)

 

Failure to use a double throw

 

 

transfer switch when connecting

 

 

to a structure's electrical system

 

 

can damage appliances and

 

 

WILL VOID the manufacturer's

 

 

warranty.

 

3- ENG

D26608

Image 3
Contents Generator Consumer Safety Information Consumer General and Service InformationRisk of Electrocution and Fire Safety Guidelines / DefinitionsImportant Safety Instructions When installing a DoubleGenerator in rain When damagedRisk of Electrocution and Fire OperationRisk of Fire Unit Indoors or in ANYConfined Area Risk of Unsafe Operation Risk of Breathing Inhalation HazardRisk of HOT Surfaces Specifications Risk of Moving PartsRisk from Lifting Grounding the Generator AssemblyRemove Generator from Carton Other Loose PartsExtension Cords Double Throw Transfer SwitchCircuit Breakers OperationKnow Your Generator Generator CapacityTo Start the Engine Connecting Electrical Loads Customer Responsibilities Table MaintenanceEngine Maintenance Generator MaintenanceStorage Engine PreparationGenerator Determining Wattage Requirements Wattage CalculationsStarting Wattage Requirements Application GuideAppliance or Load Device Typical Device Wattage Total Household Wattage CalculatorStart Troubleshooting GuideResponsibility of Original Purchaser initial User Limited WarrantyENG D26608 Quick Facts

DBSI325 specifications

The Porter-Cable DBSI325 is a highly versatile and powerful tool designed for contractors and DIY enthusiasts alike. Known for its innovative features and robust performance, this tool has gained a reputation for efficiency and reliability.

One of the standout features of the DBSI325 is its compact and lightweight design, which makes it easy to maneuver in tight spaces. Weighing in at just a few pounds, this tool allows for extended use without causing fatigue, vital for long working hours. The ergonomic handle provides a comfortable grip, ensuring precise control during operation.

This tool is equipped with a powerful motor that delivers a maximum speed, providing users with the ability to tackle a variety of tasks with ease. Whether you’re drilling through wood, metal, or masonry, the DBSI325 can handle the job. The speed settings are adjustable, allowing for greater versatility and adjustment based on the material being drilled.

Another key feature of the DBSI325 is its durable construction. Built with high-quality materials, the tool is designed to withstand the rigors of daily use on job sites. The durable housing protects the internal components, ensuring a long lifespan and minimizing the need for repairs.

Incorporating advanced technologies, the DBSI325 features a unique torque management system. This technology helps prevent over-torquing, protecting both the tool and the workpiece during operation. Additionally, the model includes a keyless chuck, which allows for quick and easy bit changes, enhancing efficiency and reducing downtime.

The depth adjustment system is another notable characteristic of the DBSI325. This feature provides precise control over drilling depth, ensuring consistent results across different projects. Whether you’re working on furniture assembly or home improvement tasks, this tool offers the accuracy required for professional-grade results.

Porter-Cable is recognized for its dedication to customer satisfaction, offering a warranty that reflects their commitment to quality. The DBSI325 is emblematic of this ethos, combining performance, durability, and user-friendly design into a single powerful tool.

In summary, the Porter-Cable DBSI325 stands out as a versatile and durable tool suitable for various applications. With its powerful motor, ergonomic design, advanced technologies, and strong construction, it is an essential addition to any toolbox, providing the performance needed to complete tasks efficiently and effectively. Whether you’re a seasoned professional or a weekend warrior, the DBSI325 is sure to meet your drilling needs.