Porter-Cable DBSI325 Risk of Electrocution and Fire, Operation, Generator in rain, Wet, icy, or

Page 4

RISK OF ELECTROCUTION AND FIRE (Continued)

HAZARD

 

WHAT CAN HAPPEN

HOW TO PREVENT IT

 

 

 

 

Operation of

Water is an excellent conductor

Operate generator in a clean, dry,

generator in rain,

of electricity! Water which comes

well ventilated area. Make sure

wet, icy, or

in contact with electrically

hands are dry before touching

flooded

charged components can

unit.

conditions.

transmit electricity to the frame

 

 

 

and other surfaces, resulting in

 

 

 

electrical shock to anyone con-

 

 

 

tacting them.

 

 

 

 

 

 

 

 

Use of worn,

Contact with worn or damaged

Inspect extension cords before

damaged, under-

extension cords could result in

use and replace with new cord if

sized or un-

electrocution.

required.

grounded exten-

 

 

 

 

 

Use of undersize extension

Use proper size (wire gauge)

sion cords.

 

cords could result in overheating

cordset for application see chart

 

of the wires or attached items,

in the Assembly section of this

 

 

resulting in fire.

manual.

 

 

 

 

 

 

 

Use of ungrounded cordsets

Always use a cordset having a

 

could prevent operation of

grounding wire with an

 

circuit breakers and result in

appropriate grounding plug. DO

 

electrical shock.

NOT use an ungrounded plug.

Placing generator

 

Accidental leakage of electrical

Place generator on low conduc-

on or against

 

current could charge conductive

tivity surface such as a concrete

highly conductive

 

surfaces in contact with the

slab.

surface, such as a

 

generator.

 

 

steel walkway or

 

 

 

ALWAYS operate generator a

metal roof.

 

 

 

minimum of six feet from any

 

 

 

 

conductive surface.

 

 

 

 

 

 

Improper

Exceeding the load capacity of

Read the load rating chart and

connection of

the generator by attaching too

instructions in the Wattage Cal-

items to

many items, or items with very

culation section. Make sure that

generator.

high load ratings to it could

the summation of electrical

 

result in overheating of some

loads for all attachments does

 

items or their attachment wiring

not exceed the load rating of the

 

resulting in fire or electrical

generator.

 

shock.

 

 

Operation of unit

 

 

 

Do not operate generator with

 

Attempting to use the unit

when damaged,

 

when it has been damaged, or

 

mechanical or electrical

or with guards or

 

when it is not functioning

 

problem. Have unit repaired by

panels removed.

 

normally could result in fire or

 

an Authorized Service Center.

 

 

electrocution.

 

 

 

 

 

 

 

 

 

 

 

Removal of guarding could

Do not operate generator with

 

 

expose electrically charged

protective guarding removed.

 

 

components and result in

 

 

 

 

electrocution.

 

 

D26608

4- ENG

Image 4
Contents Generator Consumer General and Service Information Consumer Safety InformationSafety Guidelines / Definitions Important Safety InstructionsWhen installing a Double Risk of Electrocution and FireWhen damaged Risk of Electrocution and FireOperation Generator in rainUnit Indoors or in ANY Risk of FireConfined Area Risk of Breathing Inhalation Hazard Risk of Unsafe OperationRisk of HOT Surfaces Risk of Moving Parts SpecificationsRisk from Lifting Assembly Remove Generator from CartonOther Loose Parts Grounding the GeneratorDouble Throw Transfer Switch Extension CordsOperation Know Your GeneratorGenerator Capacity Circuit BreakersTo Start the Engine Connecting Electrical Loads Maintenance Engine MaintenanceGenerator Maintenance Customer Responsibilities TableEngine Preparation StorageGenerator Wattage Calculations Determining Wattage RequirementsApplication Guide Starting Wattage RequirementsHousehold Wattage Calculator Appliance or Load Device Typical Device Wattage TotalTroubleshooting Guide StartLimited Warranty Responsibility of Original Purchaser initial UserENG D26608 Quick Facts

DBSI325 specifications

The Porter-Cable DBSI325 is a highly versatile and powerful tool designed for contractors and DIY enthusiasts alike. Known for its innovative features and robust performance, this tool has gained a reputation for efficiency and reliability.

One of the standout features of the DBSI325 is its compact and lightweight design, which makes it easy to maneuver in tight spaces. Weighing in at just a few pounds, this tool allows for extended use without causing fatigue, vital for long working hours. The ergonomic handle provides a comfortable grip, ensuring precise control during operation.

This tool is equipped with a powerful motor that delivers a maximum speed, providing users with the ability to tackle a variety of tasks with ease. Whether you’re drilling through wood, metal, or masonry, the DBSI325 can handle the job. The speed settings are adjustable, allowing for greater versatility and adjustment based on the material being drilled.

Another key feature of the DBSI325 is its durable construction. Built with high-quality materials, the tool is designed to withstand the rigors of daily use on job sites. The durable housing protects the internal components, ensuring a long lifespan and minimizing the need for repairs.

Incorporating advanced technologies, the DBSI325 features a unique torque management system. This technology helps prevent over-torquing, protecting both the tool and the workpiece during operation. Additionally, the model includes a keyless chuck, which allows for quick and easy bit changes, enhancing efficiency and reducing downtime.

The depth adjustment system is another notable characteristic of the DBSI325. This feature provides precise control over drilling depth, ensuring consistent results across different projects. Whether you’re working on furniture assembly or home improvement tasks, this tool offers the accuracy required for professional-grade results.

Porter-Cable is recognized for its dedication to customer satisfaction, offering a warranty that reflects their commitment to quality. The DBSI325 is emblematic of this ethos, combining performance, durability, and user-friendly design into a single powerful tool.

In summary, the Porter-Cable DBSI325 stands out as a versatile and durable tool suitable for various applications. With its powerful motor, ergonomic design, advanced technologies, and strong construction, it is an essential addition to any toolbox, providing the performance needed to complete tasks efficiently and effectively. Whether you’re a seasoned professional or a weekend warrior, the DBSI325 is sure to meet your drilling needs.