9. Maintenance
MA5
(1)
MA6
■MUFFLER
WARNING
•Inspect periodically, the muffler for loose fasteners, any damage or corrosion. If any sign of exhaust leakage is found, stop using the machine and have it repaired immediately.
•Note that failing to do so may result in the engine catching on fire.
■SPARK ARRESTER
•The muffler is equipped with a spark arrester to prevent red hot carbon from flying out of the exhaust outlet. Periodically inspect and clean as necessary with a wire brush. In the State of California it is required by law (Section 4442 of the California Public Resources Code) to equip a spark arrester when a gas powered tool is used in any forest covered, brush covered, or grass covered unimproved land. (MA5)
(1) spark arrester
■GEAR CASE (MA6)
•The reduction gears are lubricated by multipurpose,
•Remove the cutter holders before installing new grease to arrange for old grease to exit.
■INTAKE AIR COOLING VENT
WARNING
•Never touch the cylinder, muffler, or spark plugs with your bare hands immediately after stopping the engine. The engine can become very hot when in operation, and doing so could result in severe burns.
•When checking the machine to make sure that it is okay before using it, check the area around the muffler and remove any wood chips or leaves which have attached