Tascam CD-RW2000 owner manual Sound level drops below the threshold level for five seconds

Page 22

4 – Recording—Advanced recording

If the signal is detected from an MD, the unit enters record ready mode immediately:

level

CD stop REC pause

2

seconds

time

level

MD stop

REC pause

 

 

 

 

 

 

 

time

Note that the trigger level is not used here.

or

the sound level drops below the threshold level for five seconds

level

REC pause

5 seconds

S_LVL

time

If you set the threshold value so that only high-level signals trigger recording, remember that this will not record the start of a piece with a slow fade-in:

level

Recording starts

S_LVL

This part of the track is not recorded

time

Also remember that when recording from an analog source, the threshold should be set so that it is higher than the “noise floor” (the base level of hiss, pops and crackles which may come from an older vinyl recording, for example). If the “noise floor” is higher than the threshold, synchronized recording will not

take place (the rehearsal facility can be used here (4.5, “Rehearsal”) to help):

level

Start of track is not registered

 

Noise is higher

 

than threshold

S_LVL

 

 

time

Because synchronized recording can be turned on and off while recording is taking place, it is therefore possible to record with a synchronized automatic start, and a manual end, or vice versa.

When the source material is being played back before synchronized recording is enabled, the condi- tions under which synchronized recording will start (after synchronized recording has been enabled) are:

When the signal drops below the threshold for one second or more and then rises above the threshold again (this is the general condition, of which starting synchronized recording from a stopped or paused source is a special case):

 

Recording

 

starts

 

At least 1

level

second

S_LVL

 

 

time

Alternatively, when recording digitally from sources (MD, CD and DAT) which output track divisions, synchronized recording starts when a track division is received, regardless of the level:

Track signal from source starts recording

level

S_LVL

time

To stop synchronized recording:

1The unit must be in record mode, and the SYNC indicator in the display must be lit.

22 TASCAM CD-RW2000

Image 22
Contents CD-RW2000 Important Safety Precautions Important for U.K. CustomersImportant Safety Instructions Safety Information Table of Contents Introduction About CD-R and CD-RW discsUnpacking the CD-RW2000 Introduction-FinalizingFinalizing Environmental considerationsNever use a stabilizer or printable discs Introduction-Environmental considerationsBeware of condensation Handling of compact discsDimensional drawing Recommended media Default settingsSetting Description Default value Features of the CD-RW2000 Features of the CD-RW2000-Front panel Front panelFeatures of the CD-RW2000-Rear panel Rear panelRemote control unit Features of the CD-RW2000-Remote control unitConnections Control connections Features of the CD-RW2000-ConnectionsWord sync connections Digital Coaxial OUT jack X and DigitalTime display modes Playback operationsSimple playback operations Track searchProgrammed order playback Playback operations-Programmed order playbackRepeat play Auto Ready function Playback operations-CALL playbackCall playback Auto Cue functionInput selection Signal volumeRecording Input monitoringPlaying back tracks Recording-Basic recordingBasic recording Time display while recordingRecording-Advanced recording Advanced recording24,-30,-36,-42,-48,-54,-60,-66, and -72 dB Sound level drops below the threshold level for five seconds Automatic track division Track incrementedFade-in and fade-out Rec mute functionDigital direct While recording is in progress, press the REC Mute key FRehearsal Recording-Copy-protectionCopy-protection Play or Pause keysRecording-Rehearsal Rehearsal for synchronized recordingRehearsal for track division Unfinalizing CD-RW discs After recordingErasing Erasing tracksErasing a whole disc After recording-ErasingRefreshing a disc Specifications Reference and specificationsTroubleshooting Symptom Possible cause and remedyReference and specifications-Specifications CD-RW2000