ProForm 831.210051 manual Adjusting the Filter Cycle, Posting the Warning Sign

Page 15

ADJUSTING THE FILTER CYCLE

The spa filter cycle runs automatically to clean the water in the spa. However, the number of times that the filter cycle needs to run depends on how often the spa is used.

If many different people use the spa regularly, then the water will need to be filtered more often than if it is only used occasionally by a few. The number of daily cycles, as well as the length of the cycle can be adjusted.

The pump can run one to three filter cycles daily. To change the number of cycles, press the pump and up buttons at the same time. The number of cycles will appear in the temperature display. Use the up and down buttons to select the desired number of cycles.

Each cycle can run for 60, 120, or 180 minutes. To change the length of the cycle, press the light and up buttons at the same time. The length of the cycle will appear in the temperature display. Use the up and down buttons to select the desired cycle length.

The pump or the light may turn on while you are adjusting the filter cycle. If this happens, you can turn the pump or light off once you have finished the adjustment procedure.

POSTING THE WARNING SIGN

The warning sign, shown below, must be posted on a wall or fence, where all users of the RESTORATION 5.1 will be able to see it. Whenever the spa is moved, the sign must also be moved and reposted near the spa.

15

Image 15
Contents Mon.ÐFri., 6 a.m.Ð6 p.m. MST QUESTIONS?Model No Serial No Customer HOT LineLimited ONE Year Massage SPA Warranty Table of ContentsPage Page Page Before YOU Begin If you set up the hydrotherapy spa inside If you set up the hydrotherapy spa outsideChoosing a Location for the Hydrotherapy SPA SET-UP and Assembly Page Wiring the Restoration Access Cover Securing the SPA Cover Using the Hydrotherapy SPA Testing and Treating the Water Starting the Hydrotherapy SPASPA Shell Diagram SPA Operation Console Diagram Using the Console Posting the Warning Sign Adjusting the Filter CycleMaintenance Draining the Hydrotherapy SPA Attaching and Removing the Access CoverWater Chemistry Maintaining the Proper PH BalanceDraining the Pump Opening and Closing the CUT-OFF ValvesWinter USE and Care Adjusting the Diverter Checking and Cleaning the FilterRemoving and Cleaning the Basket Removing and Cleaning the Filter CartridgesTROUBLE-SHOOTING Symptom the SPA Continues to RUN After IT has Been Shut OFF Symptom the Water Level DropsKey No. Qty Description Part LISTÑModel NoExploded DRAWINGÑModel No Model No Ordering Replacement Parts