ProForm 831.210051 manual Symptom the Water Level Drops

Page 21

9.SYMPTOM: THE WATER LEVEL DROPS

a.Some water loss due to evaporation is normal. If rapid water loss occurs, or if you notice wet- ness on the floor around the hydrotherapy spa, then the spa shell may have a leak. Contact your local spa and pool service provider for repairs.

b.A clamp or seal inside the pump compartment may be loose. Check inside the pump compart- ment for excess water, and watch the pump unit while it is operating to see if water drips from any of the plumbing. If you can identify the location of the leak inside the spa jet unit, tight- en the clamp or replace the damaged seal.

10.SYMPTOM: THE SPA CONTINUES TO RUN AFTER IT HAS BEEN SHUT OFF

a.To turn the spa jets on high, press the Pump button once. To turn the spa jets on low, press the control twice. To turn the spa jets off, press the control three times. The spa jets will remain off for three hours, at which time they will begin running the filter cycle. At any time after the spa jets has been shut off, the pump will begin cycling the water if the temperature falls below the minimum setting. Note: If the water is already below the minimum setting, the pump will not shut off.

21

Image 21
Contents Model No Serial No QUESTIONS?Customer HOT Line Mon.ÐFri., 6 a.m.Ð6 p.m. MSTLimited ONE Year Massage SPA Warranty Table of ContentsPage Page Page Before YOU Begin If you set up the hydrotherapy spa inside If you set up the hydrotherapy spa outsideChoosing a Location for the Hydrotherapy SPA SET-UP and Assembly Page Wiring the Restoration Access Cover Testing and Treating the Water Using the Hydrotherapy SPAStarting the Hydrotherapy SPA Securing the SPA CoverSPA Shell Diagram SPA Operation Console Diagram Using the Console Posting the Warning Sign Adjusting the Filter CycleMaintenance Water Chemistry Attaching and Removing the Access CoverMaintaining the Proper PH Balance Draining the Hydrotherapy SPA Draining the Pump Opening and Closing the CUT-OFF Valves Winter USE and Care Removing and Cleaning the Basket Checking and Cleaning the FilterRemoving and Cleaning the Filter Cartridges Adjusting the DiverterTROUBLE-SHOOTING Symptom the SPA Continues to RUN After IT has Been Shut OFF Symptom the Water Level DropsKey No. Qty Description Part LISTÑModel NoExploded DRAWINGÑModel No Model No Ordering Replacement Parts