MAINTENANCE
Troubleshooting schedule
Control panel
Troubleshooting takes place from the keypad.
LED display | Possible faults | Possible action | |
|
|
| |
Green activate LED flashing. | Low battery voltage. | Charge the battery | |
|
|
| |
Error LED flashes. | Overload. | The cutting attachment is jammed. | |
Release the cutting attachment. | |||
|
| ||
|
|
| |
| Temperature deviation | Allow the machine to cool down. | |
|
|
| |
| The power trigger and the activate | Release the power trigger and the | |
| button are pressed at the same time. | machine is active. | |
|
|
| |
The machine does not run | Dirt in battery connectors. | Clean with compressed air or a soft | |
brush. | |||
|
| ||
|
|
| |
Error LED is lit with red light. | Service | Contact your service agent. | |
|
|
|
Troubleshooting the battery and/or the battery charger during charging.
Battery
LED display | Possible faults | Possible action |
|
|
|
Green activate LED flashing. | Low battery voltage. | Charge the battery |
|
|
|
|
| Use the battery in surroundings |
Error LED flashing | Temperature deviation | where temperatures are between |
|
| °C and 40 °C. |
|
|
|
|
| Check that the mains voltage |
| Over voltage | corresponds with that stated on the |
|
| rating plate on the machine. |
|
|
|
|
| Remove the battery from the battery |
|
| charger. |
|
|
|
Error LED is lit | Cell difference too much (1V) | Contact your service agent. |
|
|
|
Battery charger |
|
|
LED display | Possible faults | Possible action |
|
|
|
|
| Use the battery charger only when the |
Error LED flashing | Temperature deviation | surrounding temperature is between 5 |
|
| °C and 40 °C. |
|
|
|
Error LED is lit |
| Contact your service agent. |
|
|
|
20 – English