4.7BATTERY

4.7.1.BATTERY REMOVAL

1.Remove battery retainer.

2.Slide battery from battery box to gain access to terminal cables.

3.Observe and note cable positions on battery. See Figure 4.10.

4.Disconnect cables from battery terminals, disconnecting BLACK (Negative) cable first, then disconnect RED (Positive) last. Retain mounting bolts and nuts.

WARNING

Cables must be connected to battery terminals in the proper position. RED (Positive) cable must go to the ( + ) terminal. BLACK (Negative) cable must go to the ( - ) terminal.

4.7.2.BATTERY INSTALLATION

1.Slide battery partially into battery compartment.

2.Connect cables to battery terminals. Connect RED (Positive) cable first. Connect BLACK (Negative) cable last.

3.Reinstall battery retainer and positive terminal cover.

BATTERY REMOVAL:

DISCONNECT BLACK CABLE (NEGATIVE) FIRST,

DISCONNECT RED CABLE (POSITIVE) LAST.

BATTERY INSTALLATION:

CONNECT RED CABLE (POSITIVE) FIRST,

CONNECT BLACK CABLE (NEGATIVE) LAST.

NEGATIVE

TERMINAL

TERMINAL COVER

POSITIVE

TERMINAL

TERMINAL COVER MUST

SHIELD POSITIVE

TERMINAL AFTER

INSTALLATION

FIGURE 4.10

WARNING

The electrolyte (acid) produces a highly explosive gas. Keep all sparks, flame and fire away from area when charging battery or when handling electrolyte or battery. Electrolyte (acid) is a highly corrosive liquid. Wear eye protection. Wash affected areas immediately after having eye or skin contact with electrolyte (acid). Battery acid is corrosive. Rinse empty acid containers with water and mutilate before discarding. If acid is spilled on battery, bench, or clothing, etc., Flush with clear water and neutralize with baking soda.

4.7.3.BATTERY SERVICE

1.Remove battery.

2.Place battery in a well ventilated area on a level surface.

3.Using distilled water, refill cells as required to cover cell plates.

4.With cell caps removed, connect battery

charger to battery terminals. RED to positive

(+)terminal and BLACK to negative (-) terminal.

5. Slow charge battery at 1 amp for 10 hours. An alternative fast charge should be no more than 2.5 amps for four hours.

6. If battery will not accept charge or is partially charged after 10 hours of charging at 1 amp, replace with new battery.

(Continued on Next Page)

23

Image 23
Contents Instruction No -4370 I.R /6/01 Model Number ExplanationPreparation Protection for ChildrenProtection Against Tipovers Mount and dismount machine from left side MaintenanceOperation Table of Contents Nomenclature IntroductionEngine Stop OFF RUN on Start Glow Plug PRE-HEAT SymbolsDiesel Fuel only Symbols PRE-START Check List Operating InstructionsStarting & Stopping ENGINE, Blades & Parking Brake Starting EngineStarting Mower Blades Starting Engine from previousStopping Engine EngineParking Brake Cutting Height AdjustmentOperation Motion Control Driving Machine Check Mower Blade Service After First 5 HoursChange Engine OIL Mower Components Check Mower Drive BeltAfter Every 25 Operating Hours Before Operating Mower Riding Mower LubricationOther Lubrication Points Deck Removal Annually END of Each SeasonFrom previous Fuel Filter Diesel Engine onlyPower Transfer Shaft Removal Neutral Position Adjustments Adjustments & RepairParking Brake Adjustment Blade Sharpening Mower Blade ReplacementBlade Wear Limits from previous Engine Belt Removal Mower Drive BELT, Engine Belt & Hydro Pump Belt ReplacementMower Drive Belt Replacement Mower Drive Belt RemovalOn Next Battery Battery RemovalBattery Installation Battery ServiceDo not Overfill BatteryBattery Testing NEW Battery PreparationRemove NUT Remove Belt From Spindle Remove Blade Bolt Problem Probable Cause Corrective Action TroubleshootingProblem Probable Cause Corrective Action MAINTENANCE/REPLACEMENT Parts Service ScheduleDisclaimer of Warranty Year Limited WarrantyPage Page OUT Front Z-RIDER Hydro Drive Series