La Crosse Technology WS-8025SU instruction manual Mounting

Page 10

1.Weather Icons

a.There are 3 possible weather icons that will be displayed at various times in the center of the indoor weather station.

iSunny - indicates that the weather is expected to improve (not that the weather will be sunny).

iiSun with Clouds - indicates that the weather is expected to be fair (not that the weather will be sunny with clouds).

iiiClouds with Rain - indicates that the weather is expected to get worse (not that the weather will be rainy).

b.The weather icons change when the unit detects a change in air pressure.

c.The icons change in order, from "sunny" to "sun with clouds" to "clouds with rain" or the reverse.

d.It will not change from "sunny" directly to "clouds with rain", although it is possible for the change to occur quickly.

e.If the symbols do not change, the weather has not changed (or the change has been slow and gradual).

f.The sensitivity of the change in foreacst icon is set by the user in section F of the Detailed Set Up Guide.

H. Weather Tendency Arrows

Pressure trend arrow

1.Along with the forecast icon there is a pressure tendency arrow.

2.There is one that points up (on the left side of the LCD) and one that points down (on the right side of the LCD).

3.These arrows reflect current changes in the air pressure.

4.An arrow pointing up indicates that the air pressure is increasing and the weather is expected to improve or remain good.

5.An arrow pointing down indicates that the air pressure is decreasing and the weather is expected to become worse or remain poor.

6.No arrow means the pressure is stable.

7.A storm can be expected if there is a drop of 4 hPa or more in less than 6 hours. The clouds with rain icon will be displayed and the tendency arrow that points down will be flashing-indicating the storm warning feature has been activated. The flashing will stop when the air pressure stabilizes or begins to rise.

I. Storm Warning Alarm

1.An alarm can be set to warn of a drop in air pressure.

2.Please follow the programming instructions in section F of the Detailed Set Up Guide to activate this alarm

3.When the air pressure drops by the level set, an alarm will sound (if the alarm is activted).

4.To cancel the alarm while sounding press any key.

J.Air Pressure Tendency for Past Two Hours

The bar below the air pressure history chart displays the air pressure change over the past two hours (values based on hPa change, 1 hPa equals 0.03 inHg).

K.Barometric Air Pressure Reading

1.The actual barometric air pressure is displayed directly under the weather forecast icon

2.The relative air pressure is calibrated by the user through the programming mode.

3.Please Follow the programming instructions in section F of the Detailed Set Up Guide to set this feature.

4.To toggle between absolute and relative air pressure, press the "-" key.

L.Air Pressure History Bar Chart

1.The bar graph shows in hPa (Hekto Pascal) the recorded air pressure over the past 30- hours.

2.The horizontal axis shows the hours at increments of -30 hours, -24 hours, -18 hours, -12 hours, -6 hours, -3 hours, -1 hours, and 0 hours (current).

3.The vertical axis is set by hPa: the "0" on this axis represents the current hPa, and + or -1,3,5, or 7 shows (in hPa) how high or low the past air pressure was as compared to the current one.

4.The "0" on the vertical axis indicates the current air pressure value.

5.The "0h" on the horizontal axis indicates the current hour, thus the current air pressure also.

6.Each bar on the bar graph represents a value of 0.03 hPa, and each bar also has a corresponding value on the verticle axis.

7.Air pressure trends can be determined by simply glancing at the bar graph.

a.If the bars are rising (higher on the right than the left) then the air pressure has a rising trend, and the weather should improve.

b.If the bars are dropping (lower on the right than the left) then the air pressure has a falling trend, and the weather should worsen.

8.Multiply the two values to find past air pressure (note the + or - sign of values on the verticle axis); i.e. 0.03 hPa x 3 = 0.09 hPa, now add this value to the air pressure (in LCD 4) to evaluate what past air pressures have been.

9.The bar chart will constantly scroll to avoid burnout of the LCD.

Note : This feature cannot be turned off.

MOUNTING

Note : Before permanently mounting, ensure that the indoor weather station is able to receive signals from the transmitters and WWVB signal at the desired location. To achieve a true temperature reading, avoid mounting the remote thermo/hygro sensor (or any sensor) where direct sunlight can reach the remote sensor. We recommend that you mount the remote sensor on a North-facing wall or under an eve. The sending range of the remote thermo/hygro sensor is 200 feet(60m) however obstacles such as walls, concrete, and large metal objects can reduce the range. Place all units in their desired location, and wait approximately 15 minutes before permanently mounting to ensure that there is proper reception. If the indoor weather station loses the signal from the remote sensor, it will display the last temperature reading for 15 minutes. After 15 minutes of not receiving any signals, the remote temperature will display "- -.-".

A.Mounting the Remote Thermo/hygro Sensor

The remote thermo/hygro sensor can be mounted with the use of screws or by using the adhesive tape.

GB

P.16

P.17

GB

 

 

 

 

Image 10
Contents WS-8025SU Wireless Weather Center with Sun/Moon Time FCC ID OMO-01TX transmitter, OMO-01RX receiverContents Inventory of Contents Table of ContentsQuick SET-UP Guide Detailed SET-UP Guide Program Mode Overview of programming mode sequenceTime, 12/24 Hour Mode and Date Setting City Location SettingHawaii City Location ListingAlabama Colorado ArkansasOregon Time Zone and Daylight Saving Time SettingsOklahoma Texas UtahLCD Contrast Features and OperationsMoon Phase Sunrise/set and Moonrise/set CalculationSet Up of Multiple Units Outdoor Minimum and Maximum Temperature and HumidityMultiple Remote Temperature Sensors Remote Temperature Alarm Activating the alarmMounting Mounting with screws TroubleshootingSpecifications Mounting with Adhesive TapeDimensions L x W x H Temperature measuring rangePower supply Relative humidity rangeWarranty Information Support@lacrossetechnology.com FCC Disclaimer Table DES Matieres Guide Dinstallation RapideContenu Guide Dinstallation Detaille Mode de programmation Sommaire de la séquence du mode de programmationRéglage de lheure, du mode 12/24 heures et de la date Réglage de lemplacement de la villeListe des villes Réglages du fuseau horaire et de lheure dété Liste des villes du CanadaListe des villes du Mexique Unités de mesure météo ˚F/˚C, inHg/hPaContraste LCD Caracteristiques ET FonctionnementCalcul des heures et minutes de lheure dété Alarme de température radio-pilotée Activer lalarme Phase lunaireInstallation de plusieurs appareils Réglage de lalarme de températureIcônes météo Annuler lalarme de température pendant sa sonnerieAlarme davertissement dorage Flèches de tendance météoMontage EntretienGarantie Specifications EN CAS DE PanneInventario DE Contenido Table of ContenidoGuia Rapida DE Puesta EN Funcionamiento Guia Detallada DE Puesta EN Funcionamiento Ajuste de Hora, Modo 12/24 Horas y Fecha III. Explicación de la Información de la Pantalla LCDRepaso de la secuencia del modo de programación IV. Esquema de las Teclas de FuncionamientoCiudades de Estados Unidos, Listadas por Estado Código Lista de la localización de ciudadesCódigo Estado/Ciudad Alaska California Georgia Ajuste de Zona Horaria y Hora de Verano Listado de Ciudades de Canada CódigoCódigo Ciudad Unidades de Medición del Tiempo ˚F/˚C, inHg/hPaSalida/Puesta de Sol y Cálculo de Salida/Puesta de Luna Características Y OperaciónContraste de la Pantalla LCD Cálculo de Horas Diurnas y MinutosFase Lunar Activando la AlarmaAjuste la alarma de temperatura Mínimo y máximo Temperatura y Humedad Al Aire LibreCancelando la Alarma de Temperatura Mientras está Sonando Iconos del tiempoMontaje Cuidado Y MantenimientoSolucion DE Problemas Informacion DE LA Garantia Especificaciones
Related manuals