Davis Instruments 6152C manual Screen 7 Time Zone

Page 16

Setup Mode

The more accurate you are, the better; however, a reasonable estimate will work, too.

Screen 5: Latitude

1.Press the < and > keys to move between fields.

2.Press the + and - keys to change the settings up or down.

3.To select between SOUTH or NORTH, press 2ND and then UNITS.

4.Press DONE to move to the Longitude screen.

Screen 6: Longitude

1.Press the < and > keys to move between fields.

2.Press the + and - keys to change the settings up or down.

3.To select the East or West Hemisphere, press 2ND, then UNITS.

4.Press DONE to move to the next screen.

Screen 7: Time Zone

The console is pre-programmed with a combination of US time zones and the names of major cities representing time zones around the world. You can also configure your time zone using the Universal Time Coordinate (UTC) offset.

 

Screen 7: Time Zone

 

 

Note:

UTC offset measures the difference between the time in any time zone and a stan-

 

dard time, set by convention as the time at the Royal Observatory in Greenwich,

 

England. Hayward, California, the home of Davis Instruments, observes Pacific Stan-

 

dard Time. The UTC offset for Pacific Standard Time is -8:00, or eight hours behind

 

Universal Time (UTC). When it’s 7:00 pm (1900 hours) UTC, it’s 19 - 8 = 1100 hours,

 

or 11:00 am in Hayward in winter. When daylight saving time is observed, an hour is

 

added to the offset time automatically. Use this function in correlation with Screen 8,

 

Daylight Saving Settings.

1.Press the + and - keys to cycle through time zones.

2.If your time zone is not shown, press 2ND then press the + and - keys to set your UTC offset.

3.Press DONE to select the time zone or UTC offset shown on the screen and move to the next screen.

13

Image 16
Contents Vantage Pro2 Console Manual Vantage Pro2 Console Display Features Display FeaturesFCC Part 15 Class B Registration Warning EC EMC ComplianceTable of Contents Chapter Welcome to Vantage Pro2TM Console FeaturesKeyboard & Display Vantage Pro2 Options Console ModesOptional Sensors & Transmitting Stations Optional WeatherLink SoftwareOptional Accessories Envoys Wireless Weather Envoy #6316, Envoy8X #6318Chapter Installing the Console Powering the ConsoleInstalling the AC Power Adapter Wireless Vantage Pro2 StationsInstalling Batteries Connecting Cabled StationsTable & Shelf Placement Console LocationConsole Location Wall Mounting Chapter Using Your Weather Station Setup ModeSetup Mode Commands Mode DescriptionScreen 1 Active Transmitters Screen 2 Configuring Transmitter IDs Wireless OnlyStation Type Maximum Number Screen 3 Retransmit Wireless Only Screen 4 Time & Date Screen 5 and Screen 6 Latitude and LongitudeScreen 7 Time Zone Screen 9 Daylight Saving Status Screen 8 Daylight Saving SettingsScreen 10 Elevation Screen 11 Wind Cup Size Screen 12 Rain Collector Screen 13 Rain SeasonClear All Command Screen 14 Serial Baud RateSelecting Units of Measure Current Weather ModeSelecting Weather Variables Outside and Inside Temperature Wind Speed and DirectionHumidity Wind ChillDew Point Barometric PressureUV Ultraviolet Radiation Thsw IndexRain Rate Month-to-date precipitationYear-to-date precipitation Daily RainSolar Radiation Current Evapotranspiration ETMonthly Evapotranspiration ET Yearly Evapotranspiration ETForecast Icons Displaying the ForecastDisplaying Time & Date or Sunrise & Sunset Calibrating, Setting, and Clearing Variables Calibrating Temperature And HumidityCalibrate Wind Direction Reading Calibrating Barometric PressureSetting Weather Variables Clearing Weather VariablesHighs and Lows Mode Viewing Highs and LowsAlarm Mode Four Special AlarmsET Evapotranspiration Barometric PressureSetting Alarms UV DoseSetting the Time Alarm Variable AlarmsGraph Mode Clearing Alarm SettingsSilencing Alarms Viewing GraphsHighs Vantage Pro2 Console Graphs Weather Variable Available GraphsChapter Troubleshooting and Maintenance Vantage Pro2 Troubleshooting GuideSpeed WindTime Troubleshooting Reception ProblemsHeat Diagnostic Screen Commands Console Diagnostic ModeCheck Console Reception Screen 1 Statistical Diagnostic Screen Screen 1 Statistical Diagnostics ScreenScreen 2 Reception Diagnostic Screen Console Firmware Versions One Year Limited Warranty Console MaintenanceChanging Batteries Temperature Apparent TemperaturesAppendix a Weather Data Wind chillTemperature/Humidity/Sun/Wind Thsw Index HumidityDew Point RainSolar Radiation Barometric PressureUV Ultra Violet Radiation Skin Phototype Skin Color Tanning & Sunburn history UV MEDsCauses Sunburn UV Dose thatUV Index Leaf Wetness Evapotranspiration ETSoil Moisture Console Specifications Appendix B SpecificationsWireless Communication Specifications Console Data Display Specifications Weather Data Specifications SensorsVariable Required Resolution Range Nominal Sensors Appendix C Wireless Repeater Configuration Verifying SetupClearing Repeater ID Vantage Pro2 Console Icons Contacting Davis Technical Support