Davis Instruments 6152C manual Setting Weather Variables, Clearing Weather Variables

Page 29

Calibrating, Setting, and Clearing Variables

6.Press DONE to exit calibration.

Setting Weather Variables

You can set values for the following weather variables:

Daily Rain—Sets the daily rain total. Monthly and yearly rain totals are updated.

Monthly Rain—Sets the current months total rain. Does not affect yearly rain total.

Yearly Rain—Sets the current year’s rain total.

Daily ET (Evapotranspiration)—Sets the daily ET total. Monthly and yearly ET totals are updated.

Monthly ET—Sets the current month’s ET. Does not affect yearly total.

Yearly ET—Sets the current year’s total ET.

To set a weather variable’s value:

1.Select the variable you wish to change.

2.Press and release 2ND, then press and hold SET. The variable blinks.

3.Keep holding SET until all digits are lit and only one digit is blinking.

4.Press the < or > keys to select digits in the value.

5.Press the + and - keys to add to or subtract from the selected digit.

6.When you are finished, press DONE to exit.

Clearing Weather Variables

The following weather variables can be cleared:

Barometer—Clears any pressure offset used to calibrate the station, and the eleva- tion entry.

Wind—Clears the wind direction calibration.

Daily rain—Clearing the daily rain value is reflected in the daily rain total, the last 15 minutes of rain, the last three hours of rain sent to the forecast algorithm, the umbrella icon, and the monthly and yearly rain totals. Clear the daily rain total if the station accidentally recorded rain when the ISS was installed.

Monthly rain—Clears the monthly rain total. Does not affect the yearly rain total.

Yearly rain—Clears the yearly rain total.

Daily ET—Clears daily ET and subtracts the old daily ET total from the monthly and yearly ET totals.

Monthly ET—Clears the current monthly ET total. Does not affect the yearly ET total.

Yearly ET—Clears the current yearly ET total.

To clear a single weather variable:

1.Select the weather variable.

See “Selecting Weather Variables” on page 18.

2.Press and release 2ND, then press and hold CLEAR.

The variable you’ve chosen blinks. Keep holding the key until the value changes to zero or, in the case of the barometer, the raw barometer value. Clearing the barome- ter value also clears the elevation setting.

Clear All Command

This command clears all stored high and low weather data including monthly and yearly highs and lows and clears alarm settings all at once.

26

Image 29
Contents Vantage Pro2 Console Manual Display Features Vantage Pro2 Console Display FeaturesFCC Part 15 Class B Registration Warning EC EMC ComplianceTable of Contents Keyboard & Display Console FeaturesChapter Welcome to Vantage Pro2TM Console Modes Vantage Pro2 OptionsOptional Sensors & Transmitting Stations Optional WeatherLink SoftwareEnvoys Wireless Weather Envoy #6316, Envoy8X #6318 Optional AccessoriesPowering the Console Chapter Installing the ConsoleInstalling the AC Power Adapter Wireless Vantage Pro2 StationsConnecting Cabled Stations Installing BatteriesConsole Location Table & Shelf PlacementConsole Location Wall Mounting Setup Mode Chapter Using Your Weather StationSetup Mode Commands Mode DescriptionStation Type Maximum Number Screen 2 Configuring Transmitter IDs Wireless OnlyScreen 1 Active Transmitters Screen 3 Retransmit Wireless Only Screen 5 and Screen 6 Latitude and Longitude Screen 4 Time & DateScreen 7 Time Zone Screen 10 Elevation Screen 8 Daylight Saving SettingsScreen 9 Daylight Saving Status Screen 11 Wind Cup Size Screen 13 Rain Season Screen 12 Rain CollectorScreen 14 Serial Baud Rate Clear All CommandSelecting Weather Variables Current Weather ModeSelecting Units of Measure Wind Speed and Direction Outside and Inside TemperatureWind Chill HumidityDew Point Barometric PressureThsw Index UV Ultraviolet RadiationMonth-to-date precipitation Rain RateYear-to-date precipitation Daily RainCurrent Evapotranspiration ET Solar RadiationMonthly Evapotranspiration ET Yearly Evapotranspiration ETDisplaying Time & Date or Sunrise & Sunset Displaying the ForecastForecast Icons Calibrating Temperature And Humidity Calibrating, Setting, and Clearing VariablesCalibrate Wind Direction Reading Calibrating Barometric PressureClearing Weather Variables Setting Weather VariablesViewing Highs and Lows Highs and Lows ModeFour Special Alarms Alarm ModeET Evapotranspiration Barometric PressureUV Dose Setting AlarmsVariable Alarms Setting the Time AlarmClearing Alarm Settings Graph ModeSilencing Alarms Viewing GraphsHighs Weather Variable Available Graphs Vantage Pro2 Console GraphsVantage Pro2 Troubleshooting Guide Chapter Troubleshooting and MaintenanceSpeed WindHeat Troubleshooting Reception ProblemsTime Check Console Reception Console Diagnostic ModeDiagnostic Screen Commands Screen 1 Statistical Diagnostics Screen Screen 1 Statistical Diagnostic ScreenScreen 2 Reception Diagnostic Screen Console Firmware Versions Changing Batteries Console MaintenanceOne Year Limited Warranty Apparent Temperatures TemperatureAppendix a Weather Data Wind chillHumidity Temperature/Humidity/Sun/Wind Thsw IndexDew Point RainUV Ultra Violet Radiation Barometric PressureSolar Radiation UV MEDs Skin Phototype Skin Color Tanning & Sunburn historyUV Index UV Dose thatCauses Sunburn Soil Moisture Evapotranspiration ETLeaf Wetness Wireless Communication Specifications Appendix B SpecificationsConsole Specifications Console Data Display Specifications Sensors Weather Data SpecificationsVariable Required Resolution Range Nominal Sensors Verifying Setup Appendix C Wireless Repeater ConfigurationClearing Repeater ID Contacting Davis Technical Support Vantage Pro2 Console Icons