Graco Inc 800-706, 800-707 manual Pump Service, Servicing the Valves, Servicing the Pumping Section

Page 16

PUMP SERVICE

Servicing the Valves

1.Remove the hex valve plug.

2.Examine the o–ring under the plug for cuts or distortion and replace if worn. Lubricate new o–ring before installing.

3.Grasp valve retainer by tab at the top with pliers

and remove from valve chamber . V alve parts usually separate during removal.

Note: A special tool will be needed to remove the seat from the manifold. A reverse pliers or a standard vise grip and a 1/4” x 3” bolt to fit I.D. of seat inserted under the edge of the seat, will pry the valve seat out easily.

4.Examine all valve parts for wear and replace with preassembled valve assembly in service kit containing retainer , spring, valve, valve seat, o–ring, and back–up ring.

5.Grasp new valve assembly by tab at top with pliers,

immerse in oil and push into valve chamber . Be certain valve assembly is square in valve chamber.

6.Apply Loctite 242 to valve plug, thread into manifold port and torque per chart.

Note: Corrosion Resistant models require the coil spring installed in the Valve Plug.

Servicing the Pumping Section

Disassembly:

1.Remove the four (4) hex nuts or two (2) bolts from the manifold (varies with model).

2.Rotate crankshaft by hand to start separation of manifold from crankcase. Support the underside of the manifold and tap lightly with a mallet to remove the manifold assembly.

CAUTION

Keep manifold properly aligned with ceramic plungers when removing to avoid damage to either plungers or seals.

3.Remove oil pan and slide out seal retainer with wicks.

4.Using a wrench, loosen the plunger retainer. Grasp ceramic plunger and push toward crankcase until plunger retainer pops out.

5.Remove plunger retainer with copper gasket, back–up Ring and o–ring.

6.Remove plunger from plunger rod.

Reassembly:

1.Carefully examine each ceramic plunger for scoring or cracks, replace if worn and slip onto plunger rod.

Note: Ceramic plunger can only be installed one direction (front to back). Do not force onto rod.

2.Examine plunger retainer and stud and replace if worn.

Note: Thread stud into plunger retainer.

3.Examine o–ring, back–up ring and gasket on plunger retainer and replace if worn or cut. Lubricate o–ring for ease of installation and to avoid damaging o–rings.

Note: First install gasket, then back–up ring and o–ring.

4. Thread plunger retainer and stud assembly into plunger rod. Exercise caution not to over torque.

5.Saturate new oil wick by soaking in oil, place in seal retainer and slip retainer over ceramic plunger.

6.Replace oil pan.

7.Turn shaft by hand to line up plungers so end plungers are parallel.

8.Carefully slip manifold onto plungers, keeping manifold level, and tap with mallet to bring manifold flush with crankcase.

9.Replace washers and nuts or bolts and torque per chart.

Servicing the Seals and V–Packings

Disassembly:

1.Remove the manifold as described.

2.With crankcase side of manifold facing up, unscrew the seal case from the manifold using a special key wrench.

3.Remove o–ring from seal case.

4.Remove snap ring and low pressure seal from the seal case. Seals are generally removed easily without any tools.

5.High Pressure Seal Models: The high pressure seal is generally easily removed from the manifold without any tools. If extremely worn a reverse pliers may be used.

6. V–Packing Models: The female adapter , two v–packings and male adapter are easily removed from manifold without tools. If extremely worn a reverse pliers may be used.

16308–532

Image 16
Contents 800-706, Series a Rev a800-707, Series a General Safety Pressure Relief ProcedureSpray Gun Safety Devices Medical TreatmentHose Safety Fuel and Emission HazardsEquipment Misuse Hazard System PressureMoving Parts Hazard TermsInstallation Set UpCheck for Shipping Damage Connect to Water SupplyStartup Installing and Changing Spray Tips Trigger Safety LatchFollow the Pressure Relief Procedure Maintenance Pressure Relief ProcedureSHUTDOWN, Flushing Storage Interval What to doTroubleshooting Chart Problem Cause SolutionHydra-Cleanr3540 Pressure Washer Parts DrawingParts List Part Description QTYHydra-Cleanr4043 Pressure Washer Fuel Tank Assembly Pump Assembly Kit Repair Kit Description Qty Kit Repair Kit Description Qty 801-041804-099 Pump Service Servicing the ValvesServicing the Pumping Section Servicing the Seals and V-PackingsReassembly Servicing Crankcase SectionAccessories 800-649 3540Technical Data ModelImportant Phone Numbers Graco WarrantyGraco INC. P.O. BOX 1441 MINNEAPOLIS, MN Parts Change Notice NEW Pump Assembly Parts USE only Genuine Graco Parts and Accessories Description QtyKit Repair Kit Description

308-532, 800-706, 800-707 specifications

Graco Inc. is a well-respected name in the manufacturing industry, particularly known for its diverse portfolio of equipment designed for the construction, manufacturing, and maintenance sectors. Among their many offerings are the Graco models 308-532, 800-706, and 800-707, each of which embodies innovation and reliability.

The Graco 308-532 is a versatile airless sprayer that excels in applying coatings with precision. Built with a high-performance pump, it delivers a consistent flow, ensuring an even application of paint or other materials. This model is favored by contractors for its ability to handle various projects, from residential painting to large commercial jobs. Its lightweight design and portability make it easy to maneuver, while features like an adjustable pressure control provide users with the ability to fine-tune the spray pattern for different materials.

The Graco 800-706 takes performance up a notch with its robust hydraulic design. This airless sprayer is engineered for efficiency, equipping users to tackle larger jobs with ease. It boasts a powerful yet quiet motor, making it suitable for residential areas or indoor applications. One of the standout characteristics of the 800-706 is its advanced monitoring system that ensures optimal operation. Users appreciate its quick-change technology, allowing for seamless switch-outs between spray tips or hoses, facilitating a fast transition between different tasks without downtime.

Rounding out this trio is the Graco 800-707, a model engineered for heavy-duty applications. Known for its durability, it is designed to withstand the rigors of daily use on demanding job sites. The 800-707 features high-capacity tanks, allowing for extended work periods without frequent refilling. Its state-of-the-art filtration system guarantees that only clean material is used, preserving the integrity of the finish. Additionally, this model is equipped with smart technology that helps streamline the spraying process, providing diagnostics and maintenance alerts to keep it running at peak performance.

In summary, Graco’s 308-532, 800-706, and 800-707 models are exemplary representatives of the company's commitment to quality, innovation, and user-friendly design. Whether for small residential jobs or large-scale commercial projects, these sprayers offer a combination of performance, versatility, and reliability that is hard to match in the industry. With ongoing advancements in technology and relentless focus on customer needs, Graco continues to be a leader in the field of spraying equipment.