Graco Inc 207-860, 306-993, 205-985 warranty Troubleshooting, Problem Cause Solution

Page 10

Troubleshooting

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

Before servicing this equipment always make sure to relieve the pressure.

Note: Check all possible problems and solutions before disassembling.

Problem

Cause

Solution

Excessive surge at spray nozzle

Obstructed spray tip, valve, or hose

Clean, clear

Cleaning solution supply empty

Refill

Clogged intake filter, kinked or col-

Clean, unkink

lapsed suction hose

 

Fluid leaking from valve

Loose packing nut or worn packings

See manual 307–010

Valve will not stop dispensing

Valve not adjusted properly

See manual 307–010

 

Dirty or worn valve stem or seat

Clean, clear, or replace – See manual

 

 

307–010

Valve will not stop the pump

Cleaning solution supply empty

Refill

 

Clogged intake filter, kinked or col-

Clean, unkink

 

lapsed suction hose

 

 

Dirty or worn valve stem or seat

Clean clear, or replace – See manual

 

 

307–010

 

Dirty or worn fluid piston or packings

Service – See pump manual

Pump operating, but spray pres-

Dirty or worn fluid piston or packings

Service – See pump manual

sure low on up stroke.

 

 

Pump operating, but spray pres-

Dirty or worn fluid intake valve

Clean, clear, or replace – See pump

sure low on down stroke

 

manual

Pump operating, but spray pres-

Clogged intake filter, kinked or col-

Clean, unkink

sure low on both strokes

lapsed suction hose

 

 

Dirty or worn fluid piston or packings

Service – See pump manual

 

Dirty or worn fluid intake valve

Clean, clear, or replace – See pump

 

 

manual

 

Loose packing nut or worn packings

Tighten, replace – See pump manual

Fluid will not come from pump

Restricted air line

Check for closed valve; use larger

(hose removed)

 

supply hose

 

Pump throat packing nut too tight

Loosen

 

Pump air motor not working

Service – See pump manual

System will not spray

Restricted air line

Check for closed valve; use larger

 

 

supply hose

 

Pump air motor not working

Service – See pump manual

1￿ ￿￿￿￿￿￿￿

Image 10
Contents Model 205-985, Series C For Mounting on Open 55 Gallon Supply DrumModel 207-860, Series B Table of Contents SymbolsInjection Hazard Fire and Explosion Hazard Grounding SetupGeneral Information Connect Hoses and Mount Pump 363 Pressure Relief Procedure OperationUseful Hints Before UsingShutdown and Care of Unit Troubleshooting Problem Cause SolutionService GeneralParts Model Monark Hydra-Clean Stainless Steel Spray Tips AccessoriesStainless Steel Blasting Tips Dimensions Technical DataGraco Standard Warranty Graco Phone Number