Operation
General Information
The following instructions are for operation of the Monark 5:1 Ratio
Pressure Relief Procedure
WARNING
INJECTION HAZARD
Fluid under high pressure can be in- jected through the skin and cause serious injury. To reduce the risk of an
injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you:
Dare instructed to relieve the pressure,
Dstop spraying,
Dcheck or service any of the system equipment,
Dor install or clean the spray nozzles.
1.Lock the gun trigger safety.
2.Close the
3.Unlock the gun trigger safety.
4.Hold a metal part of the gun firmly to the side of a grounded metal pail, and trigger the gun to relieve pressure
5.Lock the gun trigger safety.
6.Open the drain valve (R, required in your system), having a container ready to catch the drainage.
7.Leave the drain valve open until you are ready to spray again.
If you suspect that the spray tip or hose is completely clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the tip guard retaining nut or hose end coupling and relieve pressure gradually, then loosen completely. Now clear the tip or hose.