Graco Inc 205-985, 306-993, 207-860 warranty Service, General

Page 11

Service

General

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

See Parts illustration for referenced items. Shut off the air supply to the pump and relieve the pressure.

Check the air line lubricator often and keep it filled with oil. Also check the pump packing nut regularly to keep it just tight enough to stop leakage, but no tighter. Use a 1/4 in. (6.3 mm) diameter rod to tighten.

To manually lubricate the motor, disconnect the air line at the motor and place 10 to 15 drops of oil in the inlet. Reconnect the air line and turn on the air to blow oil into the motor. Shut off the air supply to the pump and relieve the pressure.

Proper packing nut take-up will stop leakage. However, all the packings should be replaced after 1000 hours of operation or delivery of 120,000 gallons of solution at 2 gpm. Refer to separate pump manual.

Clean the air line filter regularly.

Remove the inlet filter (2) daily and clean it. Check it for damage that may allow contaminants to enter the pump, and replace if necessary.

Refer to the separate instruction manuals supplied with the components of your system for complete trouble- shooting and service instructions.

￿￿￿￿￿￿￿ 11

Image 11
Contents Model 207-860, Series B For Mounting on Open 55 Gallon Supply DrumModel 205-985, Series C Symbols Table of ContentsInjection Hazard Fire and Explosion Hazard General Information SetupGrounding Connect Hoses and Mount Pump 363 Operation Pressure Relief ProcedureShutdown and Care of Unit Before UsingUseful Hints Problem Cause Solution TroubleshootingGeneral ServiceParts Model Monark Hydra-Clean Stainless Steel Blasting Tips AccessoriesStainless Steel Spray Tips Technical Data DimensionsGraco Phone Number Graco Standard Warranty