Graco 249065, 2525LD, 2626LD, 246601 important safety instructions Pressure Relief

Page 7

PRESSURE RELIEF

Follow these instructions whenever you are instructed to relieve pressure, stop spraying for

more than 10 minutes, check or service the equipment, or install or clean the spray nozzle.

1. Engage trigger safety latch

TI3233A

2. Turn pressure washer off

3. Remove ignition cable from spark plug.

4. Shut off water supply. Disconnect from water.

5.Disengage trigger safety latch. Trigger gun to relieve pressure. Then re–engage the safety latch.

TI3234a

Note: If you suspect that the spray tip or hose is clogged or that pressure has not been fully relieved after following the steps above, disengage the trigger safety latch and trigger the gun to relieve pressure.

309828 7

Image 7
Contents 2626LD 2525LDTable of Contents Fuel Hazard Component Identification Fuel Initial SetupShipping Damage OilConnect to Water Supply InstallationInstall Spray Tip Connect High-Pressure Hose and GunPressure Relief Operation For Model 2525LD only , move Safety on Safety OFF Chemical Injector Operation Follow Pressure Relief Procedure,Perform Pressure Relief Procedure, Installing and Changing Spray TipsShutdown, Flushing, and Storage Ti3231a Pump Long Term more than 30 days/Winter StorageStorage Location Perform Pressure Relief Procedure Interval What to do Maintenance ChartPerform Pressure Relief Procedure Problem Cause Solution TroubleshootingPrematurely Problem Cause SolutionChanging Spray Tips Servicing Valves Pump ServicePackings Model 2525LD PartsPart Description Qty Model 2525LD Part Description QtySJV2.5G25D-F7 Repair KitsSJV2.5G25D-F7 Repair Kits Model 2626LD Model 2626LD Part Description Qty SJV2.5G27-D2105 Repair Kits SJV2.5G27-D105Model 2525LD Technical DataModel 2626LD Toll Free Graco Standard Warranty