Graco 2626LD, 2525LD, 246601, 249065 important safety instructions Shutdown, Flushing, and Storage

Page 13

Shutdown, Flushing, and Storage

1. Remove chemical injector hose from pump, if attached.

2. Trigger gun for one minute to flush pump with clear water.

3. Engage trigger safety.

TI3233A

4.For model 2525LD, adjust throttle to STOP position. Engine should turn off.

For model 2626LD, turn OFF power switch.

309828 13

Image 13
Contents 2626LD 2525LDTable of Contents Fuel Hazard Component Identification Shipping Damage Initial SetupOil FuelInstall Spray Tip InstallationConnect High-Pressure Hose and Gun Connect to Water SupplyPressure Relief Operation For Model 2525LD only , move Safety on Safety OFF Chemical Injector Operation Follow Pressure Relief Procedure,Perform Pressure Relief Procedure, Installing and Changing Spray TipsShutdown, Flushing, and Storage Ti3231a Pump Long Term more than 30 days/Winter StorageStorage Location Perform Pressure Relief Procedure Interval What to do Maintenance ChartPerform Pressure Relief Procedure Problem Cause Solution TroubleshootingPrematurely Problem Cause SolutionChanging Spray Tips Servicing Valves Pump ServicePackings Model 2525LD PartsPart Description Qty Model 2525LD Part Description QtySJV2.5G25D-F7 Repair KitsSJV2.5G25D-F7 Repair Kits Model 2626LD Model 2626LD Part Description Qty SJV2.5G27-D2105 Repair Kits SJV2.5G27-D105Model 2525LD Technical DataModel 2626LD Toll Free Graco Standard Warranty