grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in ac- cordance with all local codes and ordi- nances.
DANGER
Improper connection of the equipment- grounding conductor can result in a risk of electrocution. Check with a qualified electrician or service personnel if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the product - if it will not fit the outlet, have a proper outlet in- stalled by a qualified electrician. Do not use any type of adapter with this prod- uct.
GROUND FAULT CIRCUIT IN- TERRUPTER PROTECTION
This product is supplied with a Ground Fault Circuit Interrupter (GFCI) built into the power cord plug. This device pro- vides additional protection from the risk of electric shock. If power is interrupted in the line, the GFCI will automatically
WATER SUPPLY (Cold Water Only)
CAUTION
When connecting the water inlet to the water supply mains, local regulations of your water company must be observed. In some areas the unit must not be con- nected directly to the public drinking wa- ter supply. This is to ensure that there is no feedback of chemicals into the water supply. Direct connection via a receiver tank or backflow preventer, for example, is permitted.
Dirt in the feed water will damage the unit. To avoid this risk, we recommend fitting a water filter.
Garden hose must be at least 1/2 inch or 5/8 inch in diameter.
Flow rate of water supply must not fall below 2 GPM (gallons per minute).
Flow rate can be determined by run- ning the water for one minute into an empty
The water supply temperature must not exceed 104°F/40°C.
Never use the pressure washer to draw in water contaminated with sol- vents, e.g. paint thinners, gasoline, oil, etc.
Always prevent debris from being drawn into the unit by using a clean water source.
SAVE THESE
INSTRUCTIONS!!
English 5